The AirTAC Airtac GAFC Air Service Unit GAFC400N10LNW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC400N10LNW is a two-piece F.R.L. combination: the filter and regulator share one body, and the lubricator is mounted on the same T-bracket. Air is cleaned and set to pressure in the first unit, then a metered oil mist is added last, so oil never travels back through the regulator seat. With a 3/8" port and 1810 g mass, it suits mid-size machine headers where a compact footprint matters.
The lower-pressure regulator is set for 0.15-0.4 MPa (20-58 psi), and the 5 um element traps fine particles for sensitive valves. The nylon bowl holds 100 cc of condensate while the oil bowl holds 185 cc, and the unit has no gauge fitted - the 1/4" gauge connection is there if you add one. It operates from -5 to 70 C and must not freeze.
| Model | Airtac GAFC Air Service Unit GAFC400N10LNW |
|---|---|
| Series | GAFC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1810 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.
| GAFC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAFC300 |
| One size up | GAFC500 (curve to 7000 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a bank of precision pneumatic valves on a packaging line where the 5 um element protects fine internal passages and the lower 0.4 MPa range keeps actuation gentle.
Mount on a 3/8" header supplying a multi-station assembly machine, where the 1810 g unit needs a proper panel mount and the 185 cc oil bowl supports longer runs between refills.
Use on a test bench feeding air tools or gauges that require clean, regulated air at modest pressure, with the semi-auto drain clearing condensate each time the supply cycles.
Choose the GAFC400 body for 3/8" porting with a 6000 L/min flow curve at 0.7 MPa inlet, a step up from the GAFC300's 3500 L/min envelope. The nylon bowl is a build choice - the 1.0 MPa max and -5 to 70 C rating are identical across PC, metal, and nylon, so confirm the material suits your environment. This model has the semi-auto drain that dumps on pressure drop plus a manual drain for on-demand use, and the 5 um element means more frequent service than the standard 40 um grade.
The L type tops out at 0.4 MPa, so if your machine may ever need more pressure, this is the wrong part. No gauge is supplied, but the 1/4" connection accepts one later. The two units are orderable separately as GAFR400-10 and GAL400-10. With a 1.0 MPa max supply, you have about 0.6 MPa above the 0.4 MPa top of the range, so plan your inlet pressure carefully.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.
This F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a 1.0 MPa (145 psi) maximum and 1.5 MPa (215 psi) proof pressure. The temperature range is -5 to 70 C, and it uses ISO VG 32 oil. The drain bowl holds 100 cc, the oil bowl holds 185 cc, and the unit weighs 1810 g. The 5 um filter element is fitted, and the gauge connection is 1/4".
The N after the port code means no gauge is supplied with this unit. The 1/4" gauge connection is still there, so you can add a circular gauge later if you need to read the set pressure. Without one, you cannot verify the outlet pressure visually, so plan to add a gauge for applications where the 0.15-0.4 MPa setting must be confirmed.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.