verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC400 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC400N10LNWK

The AirTAC Airtac GAFC Air Service Unit GAFC400N10LNWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size3/8"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade5 µm
  • Bowl materialNylon
  • Drainsemi-auto + manual
  • Pressure gaugeNot fitted
  • Weight1810 g
$113.61 $124.97Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC400N10LNWK

This AirTAC GAFC400N10LNWK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator on a shared T-bracket. The 3/8in port and 1810 g mass place it in the mid-size class, suited for machine headers or multi-station lines where a compact footprint matters. It operates in the lower-pressure band of 0.15-0.4 MPa (20-58 psi), with a 5 um element for finer filtration.

The nylon bowl holds 100 cc of condensate, while the separate oil bowl holds 185 cc, so service intervals are generous for this class. No gauge is fitted; the 1/4in gauge connection allows a later addition. A reverse-flow valve is included, and the semi-auto plus manual drain pair gives both automatic dumping on pressure drop and on-demand operation.

Airtac GAFC Air Service Unit GAFC400N10LNWK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC400N10LNWK
SeriesGAFC400 F.R.L. combination
Port size3/8" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialNylon
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight1810 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC400 is 1/4" if you add one.

Model Code: Airtac GAFC Air Service Unit GAFC400N10LNWK

GAFC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
10Port size 3/8". This body offers 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/4" gauge connection.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC400 · 3/8" · curve to 6000 L/min
One size downGAFC300
One size upGAFC500 (curve to 7000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC400N10LNWK Is Used

precision_manufacturing

Precision Drilling Spindle

Feed a 3/8in line to a precision drilling spindle where the lower 0.4 MPa ceiling prevents over-force on small diameter bits, and the 5 um element keeps fine abrasive dust out of the spindle bearings.

factory

Assembly Station Header

Supply a multi-station assembly bench with regulated air at 0.3 MPa for pneumatic screwdrivers, where the 185 cc oil bowl keeps lubricant flowing to several tools between refills.

build

Leak Test Fixture

Use on a leak test fixture that requires stable low pressure around 0.2 MPa, with the semi-auto drain handling condensate from a humid compressor line without operator attention.

Is the Airtac GAFC Air Service Unit GAFC400N10LNWK the Right Air-Prep Unit?

Choose the GAFC400 body when you need 3/8in ports and a 6000 L/min flow envelope at 0.7 MPa inlet, stepping down from the GAFC500's 3/4in size when space is tighter. The nylon bowl is a material choice, not a performance upgrade; confirm it suits your environment. The semi-auto drain clears condensate on each pressure drop, with a manual backup for scheduled maintenance. The 5 um element traps finer particles than the standard 40 um, but expect more frequent element service. The lower-pressure L type tops out at 0.4 MPa, so verify your actuators never need more. No gauge is supplied; the 1/4in connection accepts one later. The reverse-flow valve is fitted per the K code. Spares are the GAFR400-10 filter-regulator and GAL400-10 lubricator. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.

Quick checklist

  • ✓ Body size for your peak flow (3/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1810 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC400N10LNWK FAQ

The GAFC400N10LNWK operates at 0.15-0.4 MPa (20-58 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C. The drain bowl holds 100 cc and the oil bowl 185 cc. Recommended lubricant is ISO VG 32. The unit weighs 1810 g.

The N code after the port means no gauge is supplied. The GAFC400 body has a 1/4in gauge connection, so you can add a circular gauge later if you need to read the set pressure. The PT thread uses an MPa/psi scale on compatible gauges.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC400N10LNWK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC400N10LNWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.