verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAFC400 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC400N10LWK

The AirTAC Airtac GAFC Air Service Unit GAFC400N10LWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size3/8"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade5 µm
  • Bowl materialNylon
  • Drainsemi-auto + manual
  • Pressure gaugeCircular, MPa / psi
  • Weight1810 g
$119.04 $130.76Save 8% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC400N10LWK

This AirTAC GAFC400N10LWK is an F.R.L. combination where the filter and regulator share one body, paired with a lubricator on a T-bracket. With a 3/8in port and a lower-pressure range of 0.15-0.4 MPa (20-58 psi), it suits applications needing precise low-pressure control. The 5 um element traps fine particles, and the nylon bowl is fitted as standard.

The 100 cc condensate bowl and 185 cc oil bowl mean less frequent attention compared to smaller units. The circular gauge reads in MPa/psi, and the semi-auto drain dumps on pressure drop while the manual drain works on demand. A reverse-flow (reflux) valve is fitted, and the whole 1810 g assembly needs a proper panel mount, not tubing support.

Airtac GAFC Air Service Unit GAFC400N10LWK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC400N10LWK
SeriesGAFC400 F.R.L. combination
Port size3/8" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialNylon
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight1810 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC400N10LWK

GAFC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
10Port size 3/8". This body offers 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR400-10 filter & regulator, GAL400-10 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC400 · 3/8" · curve to 6000 L/min
One size downGAFC300
One size upGAFC500 (curve to 7000 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC400N10LWK Is Used

precision_manufacturing

Precision Pressure Control

Use this lower-pressure F.R.L. on a precision grinding spindle or a pneumatic tensioning system that needs stable 0.15-0.4 MPa output. The 5 um element protects fine metering valves from particle wear.

factory

Assembly Line Lubrication

Feed a multi-station assembly fixture where tools need consistent oil mist. The 185 cc oil bowl keeps lubricant topped up across long shifts, and the 100 cc drain bowl handles condensate from wet shop air.

science

Lab Air Supply

Supply a laboratory pneumatic actuator or a small test rig that requires filtered, regulated, oil-misted air at low pressure. The 5 um element and lower-pressure range suit sensitive lab equipment.

Is the Airtac GAFC Air Service Unit GAFC400N10LWK the Right Air-Prep Unit?

Choose this GAFC400N10LWK when your line needs lower pressure regulation up to 0.4 MPa and fine 5 um filtration. The nylon bowl is a material choice, but confirm it suits your environment since the catalogue gives no chemical or impact data. The semi-auto and manual drains give you both automatic dumping on pressure loss and on-demand control. The PT thread comes with an MPa/psi gauge scale, and the reverse-flow valve is fitted per the K code. For spares, order the GAFR400-10 filter-regulator and GAL400-10 lubricator separately. If your line must stay oil-free, omit the lubricator and choose a plain GAFR filter-regulator instead. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range, so you have ample inlet pressure headroom for this lower-pressure unit.

Quick checklist

  • ✓ Body size for your peak flow (3/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 1810 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR400-10 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC400N10LWK FAQ

This lower-pressure unit operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It works in -5 to 70 C temperatures and needs ISO VG 32 lubricant. The drain bowl holds 100 cc and the oil bowl 185 cc, with a total weight of 1810 g.

The L type tops out at 0.4 MPa instead of 0.9 MPa, giving up about 44% of the standard ceiling. If your machine may ever need more than 0.4 MPa, this is the wrong part. The 1.0 MPa max supply still provides 0.6 MPa of headroom above the 0.4 MPa regulated top.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC400N10LWK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC400N10LWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.