The AirTAC GAFR Adjustable Filter Regulator GAFR30008LJNTK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR30008LJNTK is a filter & regulator from AirTAC, combining both functions in a single body to condition your compressed air supply. This unit filters out liquid water and solid particles, then regulates the outlet pressure to a steady level within its lower 0.15-0.4 MPa (20-58 psi) range.
This model uses a 1/4in port, a 40 um element, and a 60 cc condensate bowl. The semi-auto and manual drains are both fitted, and the unit weighs 500 g. It comes without a gauge and without a mounting bracket, and includes a reverse-flow valve as an ordering difference. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR30008LJNTK |
|---|---|
| Series | GAFR300 filter & regulator |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Bracket | Not included (J) |
| Weight | 500 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR300 is 1/8" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR300 | GA300 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| J | No bracket (J) — supplied without the mounting bracket. |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC300-08 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR300 · 1/4" · curve to 3500 L/min |
|---|---|
| One size down | GAFR200 |
| One size up | GAFR400 (curve to 7000 L/min) |
| Add a lubricator | GAFC300-08 (F.R.L. combination) |
Use this lower-pressure regulator for sensitive pneumatic controls that need a stable, reduced pressure below 0.4 MPa, such as a precision air bearing or a delicate clamping circuit.
Its 500 g weight and 1/4in port make it a fit for compact machine frames where a full-size regulator is overkill. The lack of a bracket suits panel mounting directly.
For a lab bench air supply, this unit filters particulates and sets a low, steady pressure for instruments that cannot tolerate the full line pressure.
Choose this GAFR300 body for 1/4in porting, a step up from the GAFR200's 1/8in option, with a larger 60 cc drain bowl versus 25 cc. The PC bowl is the standard build choice; the L type limits the regulated range to 0.15-0.4 MPa (20-58 psi), so confirm your system never needs more than that. The J code omits the mounting bracket, and the N code means no gauge is supplied, though the 1/8in gauge connection is there if you add one later. The semi-auto plus manual drain is fitted, and the K code adds the reverse-flow valve. If you need lubrication downstream, order the matching GAFC300-08 combination instead. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of this unit's regulated range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC300-08 combination; do not expect an oil mist from this unit.
The GAFR30008LJNTK is a filter & regulator with a 1/4in port. Its pressure range is 0.15-0.4 MPa (20-58 psi). Maximum pressure is 1.0 MPa (145 psi) and proof pressure is 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It has a 60 cc drain bowl and weighs 500 g.
The K code indicates the reverse-flow (reflux) valve is fitted. This is an ordering difference from models without the K code. The catalogue does not detail its function in our data, so we cannot explain what it does.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.