The AirTAC GAFR Adjustable Filter Regulator GAFR300C08ASNWTK is a genuine two-in-one filter & regulator — a diversion-type water/particulate filter and a balanced pressure regulator built into ONE body. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi). It has no lubricator, so it adds no oil to the airflow.
The GAFR300C08ASNWTK is a filter and regulator combined into a single body, eliminating the need for separate GAF and GAR components. It handles 1/4in ports and delivers a standard pressure range of 0.15-0.9 MPa (20-130 psi) with a 5 um filtering element.
This metal-bowl version uses a diversion structure that spins incoming air to separate liquid water and solid particles into the 60 cc drain bowl. The balanced, self-locking regulator mechanism maintains the outlet pressure steadily as supply pressure varies, and the automatic drain handles condensate without manual intervention. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAFR Adjustable Filter Regulator GAFR300C08ASNWTK |
|---|---|
| Series | GAFR300 filter & regulator |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Bracket | Included |
| Weight | 500 g |
Specifications follow the official AirTAC GAFR catalogue (pages 235-236). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFR300 is 1/8" if you add one. This unit filters and regulates only; it does not add lubrication.
| GAFR300 | GA300 series filter & regulator — sets the port range, drain-bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Mounting bracket included. |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
The filter and the regulator are ONE body here — there is no separate GAF filter or GAR regulator part to assemble. Need lubrication downstream too? Add a lubricator by ordering the matching GAFC300-08 F.R.L. combination instead.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFR300 · 1/4" · curve to 3500 L/min |
|---|---|
| One size down | GAFR200 |
| One size up | GAFR400 (curve to 7000 L/min) |
| Add a lubricator | GAFC300-08 (F.R.L. combination) |
Feed a bank of precision pneumatic valves with 5 um filtered air at a stable 0.15-0.9 MPa setpoint, protecting fine internal clearances from particle wear.
Supply clean, regulated air to a CNC machine's clamping fixtures and tool changers, with the automatic drain removing condensate during long production runs.
Provide instrument-grade air to a laboratory test bench where the 5 um element and steady regulation prevent contamination of sensitive measurement equipment.
Choose the GAFR300 body for 1/4in or 3/8in ports; the 500 g weight and 3500 L/min flow envelope (plotted at 0.7 MPa inlet) place it between the smaller GAFR200 and larger GAFR400. The metal bowl (C) suits demanding environments, while the 5 um element (W) traps finer particles than the standard 40 um for precision applications. The automatic drain (A) is ideal for unattended operation, and the included mounting bracket simplifies installation. The reverse-flow valve (K) is fitted as an ordering difference, and the NPT thread uses an MPa/psi gauge scale. Since no gauge is supplied (N), the 1/8in gauge connection allows adding one later. If oil is needed downstream, order the matching GAFC300-08 combination. With a 1.0 MPa max supply, you have about 0.1 MPa above the 0.9 MPa top of the regulated range.
Quick checklist
This is a filter and regulator only — it delivers filtered, pressure-set air with no added oil. If a downstream tool needs lubrication, add a separate lubricator or order the GAFC300-08 combination; do not expect an oil mist from this unit.
This filter & regulator has a 1/4in port, standard pressure range of 0.15-0.9 MPa (20-130 psi), max pressure of 1.0 MPa (145 psi), proof pressure of 1.5 MPa (215 psi), and operates from -5 to 70 C. The metal drain bowl holds 60 cc and the unit weighs 500 g. It uses a 5 um element and has an automatic drain.
The K code indicates a reverse-flow (reflux) valve is fitted, which is an ordering difference from standard models. The N code means no gauge is supplied, so the set pressure cannot be read directly; the 1/8in gauge connection allows adding a compatible gauge if needed.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.