The AirTAC AirTAC 4V230P-08 Solenoid Valve, 4V200 Series (4V230P08A-AM) is a genuine 5/3-way 5/3 double solenoid — pressure center solenoid valve with AM ports and an effective area of 13.6 mm² (Cv 0.8). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V230P08A-AM is a 5/3-way double-solenoid directional valve with a pressure center, built on the 4V200 mid-body and supplied on 1/4" PT (Rc tapered) ports. Two solenoids pulse the spool to extend or retract a double-acting cylinder; at center both cylinder ports A and B stay connected to supply pressure, so the piston experiences balanced pressure on both sides. This build comes wired for AC220V through a terminal box, and the -AM suffix means it is factory-fitted with an Italian AMISCO solenoid coil instead of the standard AirTAC coil - same body, same function, same ports and flow.
In this 5/3 class the 4V200 body delivers an effective area of 13.6 mm2 (Cv 0.8), a maximum cycling frequency of 3 cycles per second and an activating response of 0.05 s or less, at a valve weight of 360 g. It is a sensible flow match for double-acting cylinders in the ~O32-50 mm bore range. Note that the exact electrical rating of the AMISCO coil is not published in the standard datasheet, so please confirm the coil's VA figure with us before ordering. Always request pressure-center holding applications to include an appropriate backup - a valve alone is not a certified load brake.
| Model | AirTAC 4V230P-08 Solenoid Valve, 4V200 Series (4V230P08A-AM) |
|---|---|
| Series | 4V200 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Pressure center |
| Port size | AM |
| Exhaust port | AM |
| Effective area (Cv) | 13.6 mm² (Cv 0.8) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 360 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 13.6 mm² |
|---|---|
| Flow coefficient | Cv 0.8 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 2 | Body size (4V200) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -AM | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.
Assembly and press-fit stations where the cylinder should stay pressure-balanced on both sides between strokes, keeping the piston steady against light off-center loads without exhausting the supply.
Multi-station fixtures and jigs driven by double-acting cylinders in the O32-50 mm class, where several 4V230P valves can share one manifold base to cut piping and simplify coil wiring.
Horizontal push-and-adjust axes where both cylinder chambers stay pressurized at center, helping the rod resist minor load drift while the machine pauses mid-sequence.
Pick this model when you need both cylinder ports pressured at center - for example to resist light load drift on a horizontally moving axis or to keep a cylinder energetic between strokes. If you need the cylinder to lock still, choose the 30C closed-center version instead; if you want it to float free for manual positioning, the 30E exhaust-center version is the right call. For small bores the 4V100 (Cv 0.6) is enough, while bores beyond ~O50 mm or faster cycles step up to the 4V300 (Cv 1.65). Single valves mount inline; several stations can share an integrated manifold base for tidy piping.
For a drop-in replacement, match all five points: 4V200 body size, function code 30P (pressure center), 1/4" port with PT thread, 220V AC coil, and terminal-box entry - plus the -AM AMISCO coil option if the original valve had it.
Quick checklist
It directs compressed air to double-acting cylinders and actuators - never single-acting types, which need a 3/2 valve. With an effective area of 13.6 mm2 (Cv 0.8) and a 3 cycles-per-second ceiling, this 5/3 pressure-center version comfortably serves bores around O32-50 mm.
The -AM option fits an Italian AMISCO solenoid coil in place of the standard AirTAC coil; body, 5/3 pressure-center function, 1/4" PT ports and flow are unchanged. This unit runs on 220V AC with a terminal-box entry. Because AirTAC does not publish the AMISCO coil's VA rating, confirm the exact figure with us at order time.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.