The AirTAC Airtac GAC F.R.L. Unit GAC200C06ALNK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for single actuators, the GAC200C06ALNK is a three-unit F.R.L. combination pre-plumbed on a single L-shape bracket with quick mounting clamps. This assembly routes air through the filter, regulator and lubricator in sequence, adding oil mist downstream of the regulator seat so internal components stay clean. It features a 1/8in port, a 40 um element and a metal bowl.
Configured for low-pressure duties, the regulator operates from 0.15-0.4 MPa (20-58 psi). Because no gauge is supplied, the set pressure cannot be read without adding one to the 1/8in gauge connection. The automatic drain clears condensate from the 25 cc bowl without an operator, and a reverse-flow (reflux) valve is fitted, shown as a separate pneumatic symbol in the catalogue.
| Model | Airtac GAC F.R.L. Unit GAC200C06ALNK |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC200 is 1/8" if you add one.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF200-06 filter, GAR200-06 regulator, GAL200-06 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/8" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds clean, lubricated air at a stable low pressure to small clamping jigs on benchtop machining centers.
Conditions air for low-pressure air motors in assembly stations where a 1/8in port matches the tool inlet.
Regulates downstream pressure for delicate testing fixtures requiring a maximum 0.4 MPa operating range.
Choose this 750 g assembly for compact installations feeding a small jig or individual cylinder. If your machine requires standard pressure up to 0.9 MPa instead of the lower 0.15-0.4 MPa (20-58 psi) range, select a standard type. The metal bowl suits rugged environments, while the 40 um element balances particle capture with service life. Since the lubricator introduces oil mist downstream, choose a filter-regulator if the line must remain oil-free. Replacement parts share the same body-port suffix: GAF200-06, GAR200-06 and GAL200-06.
Stepping up to the GAC300 increases the plotted flow envelope from 1750 to 3000 L/min at 0.7 MPa inlet, but the L-type ceiling limits this unit to 44% of the standard 0.9 MPa maximum.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, uses a 40 um element, weighs 750 g, has a 25 cc drain bowl, a 36 cc oil bowl, and requires ISO VG 32 lubricant.
No gauge is supplied. The N in the option code means you must add your own gauge to the 1/8in connection if you need to read the set pressure. The default PT thread dictates a MPa/psi scale if a gauge is installed later.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.