The AirTAC Airtac GAC F.R.L. Unit GAC200N06ALNK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for compact pneumatic setups, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. It features a 1/8in port, a 40 um element and a lower pressure range of 0.15-0.4 MPa (20-58 psi). Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling. The nylon bowl and automatic drain suit unattended duty.
Weighing 750 g, this body class is designed for single actuators rather than main headers, with a flow envelope plotted to 1750 L/min at 0.7 MPa inlet. No gauge is supplied, but a 1/8in gauge connection allows adding one if needed. The reverse-flow valve is fitted, shown as a separate pneumatic symbol in the catalogue. Replacement parts use the GAF200-06, GAR200-06 and GAL200-06 codes.
| Model | Airtac GAC F.R.L. Unit GAC200N06ALNK |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC200 is 1/8" if you add one.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF200-06 filter, GAR200-06 regulator, GAL200-06 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/8" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure cylinders positioning tiny electronic components where precise force is required.
Conditions air for compact lab actuators, adding necessary oil mist for sliding seal longevity.
Regulates gentle air flow for chemical dosing valves operating safely below 0.4 MPa.
Choose this configuration for low-pressure circuits driving small jigs, ensuring the 0.15-0.4 MPa ceiling is sufficient since higher demands require the standard type. The automatic drain clears condensate from the 25 cc bowl without operator intervention, while the 36 cc oil reservoir dictates the lubricant refill frequency. If the downstream line must remain oil-free, select a filter-regulator instead. The PT thread sets a MPa/psi gauge scale for future additions, and the 40 um element balances protection with service life.
Stepping up to the GAC300 increases the plotted flow envelope to 3000 L/min at 0.7 MPa inlet, roughly 71% larger than this body's 1750 L/min curve. Keep in mind that the 0.4 MPa upper limit of this L type is 44% of the standard 0.9 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
It operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It has a 25 cc drain bowl, a 36 cc oil bowl, weighs 750 g, and uses ISO VG 32 lubricant.
The N appears after the port and means no gauge is supplied. The unit has a 1/8in gauge connection if you need to add one later. This model also includes a reverse-flow valve, which the catalogue shows as a separate pneumatic symbol.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.