verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAC200 · F.R.L. Combination (Filter + Regulator + Lubricator)

Airtac GAC F.R.L. Unit GAC200N06ALNK

The AirTAC Airtac GAC F.R.L. Unit GAC200N06ALNK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/8"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialNylon
  • Drainautomatic
  • Pressure gaugeNot fitted
  • Weight750 g
$88.53 $98.19Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAC F.R.L. Unit GAC200N06ALNK

Delivering cleaned, regulated and lubricated air for compact pneumatic setups, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. It features a 1/8in port, a 40 um element and a lower pressure range of 0.15-0.4 MPa (20-58 psi). Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling. The nylon bowl and automatic drain suit unattended duty.

Weighing 750 g, this body class is designed for single actuators rather than main headers, with a flow envelope plotted to 1750 L/min at 0.7 MPa inlet. No gauge is supplied, but a 1/8in gauge connection allows adding one if needed. The reverse-flow valve is fitted, shown as a separate pneumatic symbol in the catalogue. Replacement parts use the GAF200-06, GAR200-06 and GAL200-06 codes.

Airtac GAC F.R.L. Unit GAC200N06ALNK Technical Specifications

ModelAirtac GAC F.R.L. Unit GAC200N06ALNK
SeriesGAC200 F.R.L. combination
Port size1/8" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialNylon
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl25 cc
Capacity of oil bowl36 cc
Recommended lubricantISO VG 32 or equivalent
Weight750 g

Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC200 is 1/8" if you add one.

Model Code: Airtac GAC F.R.L. Unit GAC200N06ALNK

GAC200GA200 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
06Port size 1/8". This body offers 06 = 1/8", 08 = 1/4".
ADrain: Automatic drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/8" gauge connection.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAF200-06 filter, GAR200-06 regulator, GAL200-06 lubricator — all three share this body and port.

Size Class & Flow Envelope

  • GAC2001/8"-1/4" · 1750 L/min
  • GAC3001/4"-1/2" · 3000 L/min
  • GAC4003/8"-1/2" · 6000 L/min
  • GAC5003/4" · 7000 L/min
  • GAC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAC200 · 1/8" · curve to 1750 L/min
One size upGAC300 (curve to 3000 L/min)
Build orderFilter → bracket → regulator → lubricator

Where the Airtac GAC F.R.L. Unit GAC200N06ALNK Is Used

precision_manufacturing

Micro-Assembly Jigs

Feeds low-pressure cylinders positioning tiny electronic components where precise force is required.

handyman

Benchtop Tooling

Conditions air for compact lab actuators, adding necessary oil mist for sliding seal longevity.

science

Laboratory Dispensing

Regulates gentle air flow for chemical dosing valves operating safely below 0.4 MPa.

Is the Airtac GAC F.R.L. Unit GAC200N06ALNK the Right Air-Prep Unit?

Choose this configuration for low-pressure circuits driving small jigs, ensuring the 0.15-0.4 MPa ceiling is sufficient since higher demands require the standard type. The automatic drain clears condensate from the 25 cc bowl without operator intervention, while the 36 cc oil reservoir dictates the lubricant refill frequency. If the downstream line must remain oil-free, select a filter-regulator instead. The PT thread sets a MPa/psi gauge scale for future additions, and the 40 um element balances protection with service life.

Stepping up to the GAC300 increases the plotted flow envelope to 3000 L/min at 0.7 MPa inlet, roughly 71% larger than this body's 1750 L/min curve. Keep in mind that the 0.4 MPa upper limit of this L type is 44% of the standard 0.9 MPa ceiling.

Quick checklist

  • ✓ Body size for your peak flow (1/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 25 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 750 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.

Airtac GAC F.R.L. Unit GAC200N06ALNK FAQ

It operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It has a 25 cc drain bowl, a 36 cc oil bowl, weighs 750 g, and uses ISO VG 32 lubricant.

The N appears after the port and means no gauge is supplied. The unit has a 1/8in gauge connection if you need to add one later. This model also includes a reverse-flow valve, which the catalogue shows as a separate pneumatic symbol.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAC F.R.L. Unit GAC200N06ALNK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAC200N06ALNK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.