The AirTAC Airtac GAC F.R.L. Unit GAC200N06ALNW is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for single actuators, this AirTAC F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/8in port pairs with a 5 um element to trap fine particles before they reach precision valves. Because the lubricator sits downstream of the regulator, oil mist is added last, ensuring the regulator seat never gets fouled by fluid.
Configured for low-pressure duties, this unit regulates between 0.15-0.4 MPa (20-58 psi). It features a nylon bowl and an automatic drain that empties the 25 cc condensate sump without operator intervention. No gauge is supplied, but a 1/8in connection is ready if you need to add one to monitor downstream pressure.
| Model | Airtac GAC F.R.L. Unit GAC200N06ALNW |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC200 is 1/8" if you add one.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF200-06 filter, GAR200-06 regulator, GAL200-06 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/8" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds clean, lubricated air to delicate pneumatic micro-valves in lab automation, relying on the 5 um element to prevent internal blockages.
Conditions air for single-actuator clamping jigs on electronics assembly benches, fitting neatly into tight 1/8in ported manifolds.
Supplies stable 0.15-0.4 MPa air to sensor calibration rigs, where the automatic drain clears condensate between unattended test cycles.
Choose this 750 g assembly for compact jigs where space is tight; its 1/8in port and 25 cc drain bowl suit light-duty cycles rather than heavy plant. The automatic drain is decisive for unattended or wet lines, while the 5 um element protects instrument air at the cost of more frequent element service. If the machine must stay oil-free, omit the lubricator and choose a filter-regulator instead. Spares are available as GAF200-06, GAR200-06 and GAL200-06. Keep in mind that 0.4 MPa is 44% of the Standard type's 0.9 MPa ceiling, so confirm your application will never need more pressure before specifying this L-type unit.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure type operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, the drain bowl holds 25 cc, the oil bowl holds 36 cc, the recommended lubricant is ISO VG 32, and the unit weighs 750 g.
No, the N in the code means no gauge is supplied. The body has a 1/8in gauge connection, so you can install a separate PT-threaded gauge reading MPa/psi to monitor your 0.15-0.4 MPa downstream setting.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.