The AirTAC Airtac GAC F.R.L. Unit GAC200N06ALWK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for pneumatic setups, this assembly integrates a filter, regulator and lubricator on a single L-shape bracket. It is built for the GAC200 size class with a 1/8" port, weighing 750 g. The 5 um element captures fine particles for sensitive instrumentation, while the lower pressure type restricts the operating range to 0.15-0.4 MPa (20-58 psi). A circular gauge is fitted to read the set pressure directly.
The automatic drain clears condensate from the 25 cc bowl without an operator, which is ideal for unattended machinery. Air passes through the filter first, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat stays clean. This specific configuration includes a reverse-flow (reflux) valve, which the catalogue shows as a separate pneumatic symbol with details on its own page. If the downstream line must remain oil-free, a filter-regulator should be chosen instead.
| Model | Airtac GAC F.R.L. Unit GAC200N06ALWK |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 06 | Port size 1/8". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF200-06 filter, GAR200-06 regulator, GAL200-06 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/8" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Conditions air for sensitive laboratory benches where precise, low-pressure instrumentation requires finely filtered, lubricated supply.
Feeds small pick-and-place actuators in electronics assembly that depend on a steady 0.4 MPa supply and 5 um cleanliness.
Prepares air for delicate linear guides needing consistent oil mist to protect narrow internal seals from wear.
The nylon bowl on this unit offers a different build choice compared to the standard PC or metal options, so buyers should confirm chemical compatibility for aggressive surroundings. The 5 um element provides finer filtration than the 40 um standard, trading off more frequent element service for better protection of precision valves. Because the type is lower pressure, the outlet tops out at 0.4 MPa; if the machine may ever need more, this is the wrong part. The PT thread sets the gauge scale to MPa/psi, and the three units are separately orderable as GAF200-06, GAR200-06 and GAL200-06. The 0.4 MPa ceiling is 44% of the Standard type's 0.9 MPa maximum, quantifying exactly what the buyer gives up when choosing this lower pressure variant.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This model operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It features a 25 cc drain bowl, a 36 cc oil bowl, a 5 um element, and weighs 750 g. The recommended lubricant is ISO VG 32 or equivalent.
The K indicates that a reverse-flow (reflux) valve is fitted to this assembly. The catalogue displays this component as a separate pneumatic symbol, and its specific functional details are located on a different page of the documentation.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.