verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAC200 · F.R.L. Combination (Filter + Regulator + Lubricator)

Airtac GAC F.R.L. Unit GAC200N06ASN

The AirTAC Airtac GAC F.R.L. Unit GAC200N06ASN is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/8" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination
  • Port size1/8"
  • Pressure range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • Bowl materialNylon
  • Drainautomatic
  • Pressure gaugeNot fitted
  • Weight750 g
$77.63 $86.56Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAC F.R.L. Unit GAC200N06ASN

Delivering cleaned, regulated and lubricated air for single actuators, this AirTAC unit integrates a filter, regulator and lubricator on a shared bracket. The 1/8in port pairs with a 0.15-0.9 MPa (20-130 psi) standard pressure range and a 40 um element. Because the lubricator sits last in the sequence, oil mist enters downstream of the regulator seat to prevent fouling.

Built with a nylon bowl, the assembly carries an automatic drain that clears condensate without an operator. No gauge is supplied, but a 1/8in gauge connection allows adding one if needed. The 25 cc drain and 36 cc oil capacities dictate frequent checks compared to larger bodies, and the 750 g mass mounts cleanly to a panel rather than relying on tubing support.

Airtac GAC F.R.L. Unit GAC200N06ASN Technical Specifications

ModelAirtac GAC F.R.L. Unit GAC200N06ASN
SeriesGAC200 F.R.L. combination
Port size1/8" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.9 MPa (20 - 130 psi)
TypeStandard
Bowl materialNylon
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl25 cc
Capacity of oil bowl36 cc
Recommended lubricantISO VG 32 or equivalent
Weight750 g

Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC200 is 1/8" if you add one.

Model Code: Airtac GAC F.R.L. Unit GAC200N06ASN

GAC200GA200 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
06Port size 1/8". This body offers 06 = 1/8", 08 = 1/4".
ADrain: Automatic drain.
SStandard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/8" gauge connection.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
(blank)No reverse-flow valve.

Constituent units, orderable separately as spares: GAF200-06 filter, GAR200-06 regulator, GAL200-06 lubricator — all three share this body and port.

Size Class & Flow Envelope

  • GAC2001/8"-1/4" · 1750 L/min
  • GAC3001/4"-1/2" · 3000 L/min
  • GAC4003/8"-1/2" · 6000 L/min
  • GAC5003/4" · 7000 L/min
  • GAC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAC200 · 1/8" · curve to 1750 L/min
One size upGAC300 (curve to 3000 L/min)
Build orderFilter → bracket → regulator → lubricator

Where the Airtac GAC F.R.L. Unit GAC200N06ASN Is Used

precision_manufacturing

Small Pneumatic Jigs

Conditions air for compact testing jigs where a single small-bore cylinder executes repetitive clamping tasks.

handyman

Benchtop Tooling

Supplies regulated, lubricated air to miniature air motors on electronics assembly benches without occupying much space.

science

Laboratory Actuators

Feeds isolated actuator points in lab automation equipment, using the automatic drain to handle condensate autonomously.

Is the Airtac GAC F.R.L. Unit GAC200N06ASN the Right Air-Prep Unit?

Choose this configuration for tight installations feeding a small jig, noting that the automatic drain suits unattended or wet lines. The nylon bowl suits standard plant conditions, while the 40 um element balances protection with service life. If the downstream line must stay oil-free, select a filter-regulator instead of this combination. For maintenance, the assembly accepts GAF200-06, GAR200-06 and GAL200-06 spares. Stepping up to the GAC300 body shifts the plotted flow envelope from 1750 to 3000 L/min at 0.7 MPa inlet, an increase of roughly 1.7x.

Quick checklist

  • ✓ Body size for your peak flow (1/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 25 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 750 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.

Airtac GAC F.R.L. Unit GAC200N06ASN FAQ

This model operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It features a 25 cc drain bowl, a 36 cc oil bowl, and weighs 750 g. The recommended lubricant is ISO VG 32.

The N in the product code indicates no gauge is supplied. The unit has a 1/8in gauge connection, so you can install a separate gauge reading in MPa or psi to match the default PT thread and verify your 0.15-0.9 MPa settings.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAC F.R.L. Unit GAC200N06ASN

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAC200N06ASN and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.