Airtac GAC F.R.L. Unit GAC200N06LWK

The AirTAC Airtac GAC F.R.L. Unit GAC200N06LWK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/8"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade5 µm
  • Bowl materialNylon
  • Drainsemi-auto + manual
  • Pressure gaugeCircular, MPa / psi
  • Weight750 g
$85.28 $94.73Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAC F.R.L. Unit GAC200N06LWK

Delivering cleaned, regulated and lubricated air for compact pneumatics, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. It features a 1/8in port, a 5 um element for fine particle capture, and a nylon bowl. The lower-pressure type restricts the operating range to 0.15-0.4 MPa (20-58 psi). A circular gauge reading MPa/psi is fitted to monitor the set pressure.

The assembly uses quick mounting clamps, eliminating inter-unit tubing and leak paths. Condensate is managed by a 25 cc drain bowl paired with a 36 cc oil reservoir, making the 750 g assembly suited for single actuators or small jigs. The reverse-flow valve is fitted, shown in the catalogue as a separate pneumatic symbol. If the downstream line must remain oil-free, omit the lubricator and choose a filter-regulator instead.

Airtac GAC F.R.L. Unit GAC200N06LWK Technical Specifications

ModelAirtac GAC F.R.L. Unit GAC200N06LWK
SeriesGAC200 F.R.L. combination
Port size1/8" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialNylon
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl25 cc
Capacity of oil bowl36 cc
Recommended lubricantISO VG 32 or equivalent
Weight750 g

Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAC F.R.L. Unit GAC200N06LWK

GAC200GA200 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
06Port size 1/8". This body offers 06 = 1/8", 08 = 1/4".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAF200-06 filter, GAR200-06 regulator, GAL200-06 lubricator — all three share this body and port.

Size Class & Flow Envelope

  • GAC2001/8"-1/4" · 1750 L/min
  • GAC3001/4"-1/2" · 3000 L/min
  • GAC4003/8"-1/2" · 6000 L/min
  • GAC5003/4" · 7000 L/min
  • GAC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAC200 · 1/8" · curve to 1750 L/min
One size upGAC300 (curve to 3000 L/min)
Build orderFilter → bracket → regulator → lubricator

Where the Airtac GAC F.R.L. Unit GAC200N06LWK Is Used

precision_manufacturing

Micro-Assembly Jigs

Feeds clean, lubricated air to small pneumatic grippers handling delicate electronics assembly where low actuation forces are required.

science

Laboratory Automation

Conditions air for low-pressure analytical instruments and small test fixtures, ensuring fine 5 um filtration protects sensitive valves.

handyman

Miniature Actuators

Supplies a steady 0.4 MPa ceiling for small-bore cylinders in light-duty clamping tasks without overpowering the mechanism.

Is the Airtac GAC F.R.L. Unit GAC200N06LWK the Right Air-Prep Unit?

This model uses a 5 um element, trapping far finer particles than the standard 40 um grade for precision valves, at the cost of more frequent element service. The nylon bowl offers a lightweight alternative to metal or PC, though buyers must confirm compatibility with aggressive surroundings. A semi-auto and manual drain pair is fitted; the semi-auto dumps condensate on each pressure drop, while the manual operates on demand. Spares are ordered individually as GAF200-06, GAR200-06 and GAL200-06. The catalogue flow curve for the GAC200 is plotted to 1750 L/min at 0.7 MPa inlet, which is about 58% of the GAC300's 3000 L/min envelope. Because the L type tops out at 0.4 MPa, it provides only 44% of the Standard type's 0.9 MPa ceiling.

Quick checklist

  • ✓ Body size for your peak flow (1/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 25 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 750 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.

Airtac GAC F.R.L. Unit GAC200N06LWK FAQ

This lower-pressure unit operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It features a 25 cc drain bowl, a 36 cc oil bowl, and weighs 750 g. The recommended lubricant is ISO VG 32.

The K indicates that a reverse-flow (reflux) valve is attached. The catalogue shows this as a separate pneumatic symbol with details on its own page, representing an ordering difference for this specific assembly.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAC F.R.L. Unit GAC200N06LWK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAC200N06LWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.