The AirTAC GAC F.R.L. Unit GAC30015ASNW is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This GAC30015ASNW is a three-unit F.R.L. combination - filter, regulator and lubricator - pre-assembled on a single L-shape bracket with quick mounting clamps, so there is no inter-unit tubing to leak. With a 1/2in port and a 1300 g mass, it belongs to the GAC300 size class and needs a proper panel or frame mount rather than support from the piping.
The 5 um element traps far finer particles than the standard 40 um grade, which suits precision valves or instrument air, though it will need more frequent element service. Pressure regulation spans 0.15-0.9 MPa (20-130 psi), and the automatic drain clears condensate from the 60 cc bowl without an operator, making it a strong fit for unattended or wet lines. The PC bowl is the standard build choice; confirm compatibility if the surroundings are aggressive, since the catalogue gives no solvent or impact data for it.
| Model | Airtac GAC F.R.L. Unit GAC30015ASNW |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-15 filter, GAR300-15 regulator, GAL300-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/2" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feed a bank of 1/2in-port pneumatic valves on a packaging machine, where the 5 um element protects fine internal clearances from particle wear.
Mount on a ring main feeding a multi-station assembly line; the automatic drain clears condensate from the 60 cc bowl without scheduled operator visits.
Condition air for a test rig with sensitive pressure regulators, relying on the 0.15-0.9 MPa range to hold a stable setpoint for repeatable results.
Choose the GAC300 body when 1/2in ports and a 1300 g unit are appropriate; the flow curve is plotted to 3000 L/min at 0.7 MPa inlet, which is about half the GAC400's 6000 L/min envelope if you need to size up. The automatic drain (A) is the right call for wet or unattended lines, while the blank drain option ships both semi-auto and manual drains. No gauge is supplied on this model, so the set pressure cannot be read without adding one - the gauge connection is 1/8in if fitted later. The 5 um element trades more frequent service for finer filtration, and the PT thread carries a MPa/psi gauge scale. Spares are GAF300-15, GAR300-15 and GAL300-15, all sharing the same body-port suffix. Since the lubricator adds oil mist downstream of the regulator, choose a filter-regulator instead if the line must stay oil-free. With a 1.0 MPa maximum supply and a 0.9 MPa top setting, there is only about 0.1 MPa of regulation headroom, so plan a supply near 1.0 MPa if you truly need 0.9 MPa out.
AirtacDistr lists every GAC300-15 order code with its price on one page at https://airtacdistr.com/products/airtac-gac300-15-three-unit-frl
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
It operates at 0.15-0.9 MPa (20-130 psi) with a 1.0 MPa (145 psi) maximum and a 1.5 MPa (215 psi) proof pressure. The temperature range is -5 to 70 C, the drain bowl holds 60 cc, the oil bowl holds 98 cc, and it weighs 1300 g. Recommended lubricant is ISO VG 32.
The N after the port code means no gauge is supplied. The body has a 1/8in gauge connection, so you can add a circular gauge later, but until then the outlet pressure cannot be read directly on the unit.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.