The AirTAC GAC F.R.L. Unit GAC30015ASNWK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for mid-size pneumatic setups, this GAC30015ASNWK assembly integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/2in port serves machines needing a standard 0.15-0.9 MPa (20-130 psi) operating range, while the 5 um element captures fine particulates before they reach sensitive valves. An automatic drain empties the 60 cc condensate bowl without operator intervention, and a reverse-flow (reflux) valve is fitted, shown as a separate pneumatic symbol in the catalogue.
Air travels through the filter first, then the regulator, with oil mist injected last so the regulating seat stays clean. Because the N in the code follows the port, no pressure gauge is supplied; the 1/8in gauge connection allows a separate instrument to be added later. The 98 cc oil bowl sets the lubrication refill interval, and the 1300 g mass requires a firm panel mount rather than tubing support.
| Model | Airtac GAC F.R.L. Unit GAC30015ASNWK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-15 filter, GAR300-15 regulator, GAL300-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/2" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds 1/2in actuated gates and sorters on a high-speed packaging conveyor, where the 5 um element protects directional valves from fine grit.
Conditions air for multi-station textile looms, relying on the automatic drain to clear condensate continuously during humid production runs.
Supplies regulated, lubricated air to test fixtures and clamping cylinders, benefiting from the reverse-flow valve fitted to this specific assembly.
Choose this configuration when a 1/2in line requires fine 5 um filtration and unattended condensate removal via the automatic drain. The PC bowl suits standard -5 to 70 C environments, but compatibility should be confirmed for aggressive surroundings. If the application must remain oil-free, omit the lubricator and select a filter-regulator instead. For maintenance, the individual elements are separately orderable as GAF300-15, GAR300-15 and GAL300-15.
Sizing against a larger neighbour, the GAC300 flow curve is plotted to 3000 L/min at 0.7 MPa inlet, which is 50% of the GAC400's 6000 L/min envelope. Regarding supply pressure, the 1.0 MPa maximum inlet leaves only about 0.1 MPa of headroom above the 0.9 MPa standard setting, so plan a supply near 1.0 MPa if you truly need maximum output.
AirtacDistr lists every GAC300-15 order code with its price on one page at https://airtacdistr.com/products/airtac-gac300-15-three-unit-frl
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It handles temperatures from -5 to 70 C, uses a 60 cc drain bowl and a 98 cc oil bowl, weighs 1300 g, and requires ISO VG 32 or equivalent lubricant.
The N positioned after the 1/2in port code indicates no gauge is supplied. The body features a 1/8in gauge connection, allowing operators to install a separate PT-threaded gauge reading in MPa/psi to monitor the 0.15-0.9 MPa set pressure.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.