The AirTAC GAC F.R.L. Unit GAC40015LWK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for mid-size pneumatics, this AirTAC F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/2in ported body operates in the lower pressure range of 0.15-0.4 MPa (20-58 psi) and uses a 5 um element to capture fine particulates for sensitive valves. A circular gauge reading MPa/psi is fitted for the default PT thread.
Air passes through the filter, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. Condensate is managed by a semi-auto and manual drain pair emptying into a 100 cc bowl, while the 185 cc oil reservoir dictates the lubricant refill cycle. This 2390 g assembly includes a reverse-flow (reflux) valve, which the catalogue shows as a separate pneumatic symbol with details on its own page.
| Model | Airtac GAC F.R.L. Unit GAC40015LWK |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure actuated valves and grippers on analytical instruments requiring finely filtered, oil-misted air at stable sub-0.4 MPa pressures.
Conditions air for delicate pouch-sealing cylinders where a 5 um element protects narrow internal clearances from abrasive dust.
Supplies regulated 1/2in air to low-force sandblasting or texturing jigs, ensuring consistent surface finishes without over-pressurizing the nozzle.
Choose this 1/2in body for duties requiring highly filtered, low-pressure air, stepping up from the GAC300 which offers a 3000 L/min plotted flow envelope at 0.7 MPa inlet compared to the 6000 L/min envelope of this GAC400. The 5 um element traps far finer particles than the standard 40 um grade, trading away element service life for precision instrument protection. Because the lubricator introduces oil mist downstream, select a separate filter-regulator if the line must remain oil-free. Should a component fail, the assembly splits into GAF400-15, GAR400-15 and GAL400-15 spares sharing the exact same body and port. Remember that the 0.4 MPa upper limit is 44% of the Standard type's 0.9 MPa ceiling, so never specify this L type if the machine might later need higher pressure.
AirtacDistr lists every GAC400-15 order code with its price on one page at https://airtacdistr.com/products/airtac-gac400-15-three-unit-frl
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi), with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 2390 g, features a 100 cc drain bowl and a 185 cc oil bowl, and recommends ISO VG 32 lubricant.
The K indicates a reverse-flow (reflux) valve is fitted. The catalogue draws this as a distinct pneumatic symbol, and you should confirm from datasheet page 235 for specific functional details regarding its operation in your system.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.