The AirTAC Airtac GAC F.R.L. Unit GAC400C15ALWK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for mid-size pneumatic setups, this GAC400C15ALWK combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/2in port pairs with a 2390 g body mass, requiring a firm panel mount rather than tubing support. It features a 5 um element for capturing fine particles and operates within the 0.15-0.4 MPa (20-58 psi) lower pressure band.
Air passes through the filter, then the regulator, and finally the lubricator, ensuring oil mist is introduced downstream so the regulator seat stays clean. The metal bowl houses a 100 cc condensate capacity and a 185 cc oil reservoir, while the automatic drain clears liquid without an operator. A reverse-flow (reflux) valve is fitted, shown as a separate pneumatic symbol in the catalogue, and a circular gauge reading MPa/psi is included for the default PT thread.
| Model | Airtac GAC F.R.L. Unit GAC400C15ALWK |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds sensitive directional control valves requiring low 0.4 MPa operating pressure and 5 um filtered, lubricated air to prevent sticking.
Conditions air for pneumatic grippers and diverters on mid-size packaging equipment where the 1/2in port and 6000 L/min envelope handle high cycle volumes.
Supplies stable low-pressure air to analytical instruments, using the metal bowl for solvent resistance and the automatic drain for unattended operation.
Choose this configuration when a machine requires low-pressure operation capped at 0.4 MPa, as the L type is the wrong part if the application might ever need standard pressures up to 0.9 MPa. The 5 um element traps far finer particles than the 40 um standard, suiting precision valves or instrument air at the cost of more frequent element service. If the downstream line must remain oil-free, omit the lubricator and choose a filter-regulator instead. The metal bowl suits harsher environments, and replacement spares follow the body-port suffix: GAF400-15, GAR400-15 and GAL400-15. The catalogue flow curve for the GAC400 is plotted to 6000 L/min at 0.7 MPa inlet, exactly double the GAC300's 3000 L/min envelope, providing clear sizing headroom. Because the L type tops out at 0.4 MPa, it provides only 44% of the Standard type's 0.9 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 2390 g, and pairs a 100 cc drain bowl with a 185 cc oil bowl. The recommended lubricant is ISO VG 32.
The K indicates a reverse-flow (reflux) valve is attached. The catalogue depicts this as a distinct pneumatic symbol with full details provided on its own page; it is an ordering difference that modifies the unit's internal air path.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.