verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAC400 · F.R.L. Combination (Filter + Regulator + Lubricator)

Airtac GAC F.R.L. Unit GAC400C15ASK

The AirTAC Airtac GAC F.R.L. Unit GAC400C15ASK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination
  • Port size1/2"
  • Pressure range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • Bowl materialMetal
  • Drainautomatic
  • Pressure gaugeCircular, MPa / psi
  • Weight2390 g
$148.48 $162.19Save 8% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAC F.R.L. Unit GAC400C15ASK

Delivering cleaned, regulated and lubricated air for demanding pneumatic setups, this AirTAC F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/2in port pairs with a standard 0.15-0.9 MPa (20-130 psi) operating range and a 40 um element. Because the assembly arrives pre-plumbed via quick mounting clamps, installers avoid inter-unit tubing leaks and only need to secure one bracket to the panel. The 2390 g mass dictates a firm frame mount rather than relying on downstream piping for physical support.

Air travels through the filter, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. This specific configuration uses a robust metal bowl and an automatic drain that expels condensate without an operator, which is highly effective for unattended machinery. A circular gauge is fitted to read the set pressure in MPa/psi, and the reverse-flow (reflux) valve is included, shown in the catalogue as a separate pneumatic symbol. If the application requires completely oil-free downstream air, omit the lubricator and select a standalone filter-regulator instead.

Airtac GAC F.R.L. Unit GAC400C15ASK Technical Specifications

ModelAirtac GAC F.R.L. Unit GAC400C15ASK
SeriesGAC400 F.R.L. combination
Port size1/2" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.9 MPa (20 - 130 psi)
TypeStandard
Bowl materialMetal
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight2390 g

Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAC F.R.L. Unit GAC400C15ASK

GAC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
CBowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N).
15Port size 1/2". This body offers 10 = 3/8", 15 = 1/2".
ADrain: Automatic drain.
SStandard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.

Size Class & Flow Envelope

  • GAC2001/8"-1/4" · 1750 L/min
  • GAC3001/4"-1/2" · 3000 L/min
  • GAC4003/8"-1/2" · 6000 L/min
  • GAC5003/4" · 7000 L/min
  • GAC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAC400 · 1/2" · curve to 6000 L/min
One size downGAC300
One size upGAC500 (curve to 7000 L/min)
Build orderFilter → bracket → regulator → lubricator

Where the Airtac GAC F.R.L. Unit GAC400C15ASK Is Used

factory

Automotive Assembly Lines

Feeds main air headers for robotic welding cells where a 1/2in supply and automatic condensate removal keep heavy-duty cylinders running without manual intervention.

packaging

Case Erector Machines

Provides consistent 0.9 MPa air and oil mist to the folding and sealing actuators, preventing premature wear on high-speed moving parts.

precision_manufacturing

CNC Tooling Preparation

Conditions air for automatic tool changers and pneumatic clamps, ensuring the 40 um element captures debris before it reaches precision valves.

Is the Airtac GAC F.R.L. Unit GAC400C15ASK the Right Air-Prep Unit?

Choose this GAC400 size class when a 1/2in port is required but the 3/8in GAC400 option is too restrictive, or step up to the GAC500 with its 3/4in port if the line demands a higher flow envelope (plotted to 7000 L/min at 0.7 MPa inlet versus 6000 L/min here). The metal bowl offers durability for harsh environments, while the automatic drain clears the 100 cc condensate sump autonomously. The standard 40 um element suits general plant air, but precision valves might need the 5 um W option. The fitted gauge reads in MPa/psi for the default PT thread, and the reverse-flow valve is attached. Should a component fail, order the exact spares GAF400-15, GAR400-15 and GAL400-15. Remember that the 1.5 MPa (215 psi) proof pressure provides a 1.5x burst-test margin over the 1.0 MPa (145 psi) maximum, which is not permission to run above 1.0 MPa.

Quick checklist

  • ✓ Body size for your peak flow (1/2" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 2390 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.

Airtac GAC F.R.L. Unit GAC400C15ASK FAQ

This standard type unit operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It features a 1/2in port, a 100 cc drain bowl, a 185 cc oil bowl, a 40 um element, and weighs 2390 g. The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32.

The K indicates that a reverse-flow (reflux) valve is fitted to this assembly. The official catalogue displays this as a distinct pneumatic symbol with further details provided on its own dedicated page.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAC F.R.L. Unit GAC400C15ASK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAC400C15ASK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.