The AirTAC Airtac GAC F.R.L. Unit GAC400N15ALNK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for mid-size pneumatics, this GAC400 unit combines a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. It features a 1/2in port, a 40 um element and a nylon bowl. The lower-pressure type restricts the operating range to 0.15-0.4 MPa (20-58 psi). An automatic drain clears condensate without an operator, and a reverse-flow valve is fitted.
Air passes through the filter, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. No gauge is supplied, but a 1/4in gauge connection allows adding one to read the set pressure. If the downstream line must remain oil-free, omit the lubricator and choose a filter-regulator instead. The 100 cc drain bowl and 185 cc oil bowl dictate the service interval, and the 2390 g mass requires a firm panel mount rather than tubing support.
| Model | Airtac GAC F.R.L. Unit GAC400N15ALNK |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 1/2" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC400 is 1/4" if you add one.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 15 | Port size 1/2". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 1/2" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds looms and spinning frames where a lower 0.4 MPa ceiling protects delicate yarn tensioning cylinders from overpressure.
Provides steady low-pressure air for folding and gluing stations, with the automatic drain handling condensate in humid environments.
Conditions air for pneumatic stops and diverters, adding oil mist downstream of the regulator to keep moving parts lubricated.
Choose this nylon-bowl model for unattended lines where the automatic drain prevents condensate buildup. The 1/2in port suits heavier duties than the GAC300, and the catalogue flow curve for the GAC400 is plotted to 6000 L/min at 0.7 MPa inlet, double the GAC300 envelope. The 40 um element handles general plant air, while the lower-pressure type limits the ceiling to 0.4 MPa. Because no gauge is supplied, operators must add one to the 1/4in connection to verify settings. The reverse-flow valve is shown as a separate pneumatic symbol in the catalogue. Spares follow the body-port suffix: GAF400-15, GAR400-15 and GAL400-15. Remember that 0.4 MPa is 44% of the standard 0.9 MPa ceiling, so verify your machine never requires higher pressure before selecting this L type.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This unit operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It has a 100 cc drain bowl, a 185 cc oil bowl, and weighs 2390 g. The recommended lubricant is ISO VG 32.
The N in the code means no gauge is supplied. The body features a 1/4in gauge connection, allowing you to install a separate gauge reading MPa/psi for the default PT thread to monitor the 0.15-0.4 MPa range.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.