verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAC400 · F.R.L. Combination (Filter + Regulator + Lubricator)

Airtac GAC F.R.L. Unit GAC400N15ALNK

The AirTAC Airtac GAC F.R.L. Unit GAC400N15ALNK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/2" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/2"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialNylon
  • Drainautomatic
  • Pressure gaugeNot fitted
  • Weight2390 g
$143.01 $156.35Save 8% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAC F.R.L. Unit GAC400N15ALNK

Delivering cleaned, regulated and lubricated air for mid-size pneumatics, this GAC400 unit combines a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. It features a 1/2in port, a 40 um element and a nylon bowl. The lower-pressure type restricts the operating range to 0.15-0.4 MPa (20-58 psi). An automatic drain clears condensate without an operator, and a reverse-flow valve is fitted.

Air passes through the filter, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. No gauge is supplied, but a 1/4in gauge connection allows adding one to read the set pressure. If the downstream line must remain oil-free, omit the lubricator and choose a filter-regulator instead. The 100 cc drain bowl and 185 cc oil bowl dictate the service interval, and the 2390 g mass requires a firm panel mount rather than tubing support.

Airtac GAC F.R.L. Unit GAC400N15ALNK Technical Specifications

ModelAirtac GAC F.R.L. Unit GAC400N15ALNK
SeriesGAC400 F.R.L. combination
Port size1/2" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialNylon
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight2390 g

Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC400 is 1/4" if you add one.

Model Code: Airtac GAC F.R.L. Unit GAC400N15ALNK

GAC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
15Port size 1/2". This body offers 10 = 3/8", 15 = 1/2".
ADrain: Automatic drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/4" gauge connection.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAF400-15 filter, GAR400-15 regulator, GAL400-15 lubricator — all three share this body and port.

Size Class & Flow Envelope

  • GAC2001/8"-1/4" · 1750 L/min
  • GAC3001/4"-1/2" · 3000 L/min
  • GAC4003/8"-1/2" · 6000 L/min
  • GAC5003/4" · 7000 L/min
  • GAC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAC400 · 1/2" · curve to 6000 L/min
One size downGAC300
One size upGAC500 (curve to 7000 L/min)
Build orderFilter → bracket → regulator → lubricator

Where the Airtac GAC F.R.L. Unit GAC400N15ALNK Is Used

factory

Textile Machinery

Feeds looms and spinning frames where a lower 0.4 MPa ceiling protects delicate yarn tensioning cylinders from overpressure.

packaging

Carton Sealing Lines

Provides steady low-pressure air for folding and gluing stations, with the automatic drain handling condensate in humid environments.

conveyor_belt

Light Assembly Conveyors

Conditions air for pneumatic stops and diverters, adding oil mist downstream of the regulator to keep moving parts lubricated.

Is the Airtac GAC F.R.L. Unit GAC400N15ALNK the Right Air-Prep Unit?

Choose this nylon-bowl model for unattended lines where the automatic drain prevents condensate buildup. The 1/2in port suits heavier duties than the GAC300, and the catalogue flow curve for the GAC400 is plotted to 6000 L/min at 0.7 MPa inlet, double the GAC300 envelope. The 40 um element handles general plant air, while the lower-pressure type limits the ceiling to 0.4 MPa. Because no gauge is supplied, operators must add one to the 1/4in connection to verify settings. The reverse-flow valve is shown as a separate pneumatic symbol in the catalogue. Spares follow the body-port suffix: GAF400-15, GAR400-15 and GAL400-15. Remember that 0.4 MPa is 44% of the standard 0.9 MPa ceiling, so verify your machine never requires higher pressure before selecting this L type.

Quick checklist

  • ✓ Body size for your peak flow (1/2" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 2390 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.

Airtac GAC F.R.L. Unit GAC400N15ALNK FAQ

This unit operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It has a 100 cc drain bowl, a 185 cc oil bowl, and weighs 2390 g. The recommended lubricant is ISO VG 32.

The N in the code means no gauge is supplied. The body features a 1/4in gauge connection, allowing you to install a separate gauge reading MPa/psi for the default PT thread to monitor the 0.15-0.4 MPa range.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAC F.R.L. Unit GAC400N15ALNK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAC400N15ALNK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.