AirTAC GFC200 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC200-06 Combination Unit (GFC20006NT)

The AirTAC GFC200-06 Combination Unit (GFC20006NT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/8" ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$52.20 $59.70Save 12% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC200-06 drain, gauge and thread option on one page All GFC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC200-06 Combination Unit (GFC20006NT)

The AirTAC GFC series is a two-unit air preparation set: a filter regulator plus a lubricator, giving filtration, pressure regulation and oil-mist lubrication in one station. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. With the default drain there is no drain letter in the code, and the blank gauge position of the K-free, gauge-lettered variants is replaced here by N for no gauge. Downstream pressure is set on the regulator within the differential-drain range of 0.15-0.9 MPa (20-130 psi), with a maximum working pressure of 1.0 MPa (145 psi).

This is a genuine AirTAC part. The G series comes in 200, 300, 400 and 600 sizes with ports from 1/8" to 1", 40 um standard or 5 um (W) filter grades, differential-pressure, automatic or manual drains, gauge options, and three thread types (NPT on this code). Working temperature is -5 to 70 C (non-freezing) and the 200-size bowls are polycarbonate. Flow is published as curves rather than a single rating, so we confirm datasheet and flow figures for your circuit on request. Order code GFC20006NT has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GFC200-06 Combination Unit (GFC20006NT) Technical Specifications

ModelAirTAC GFC200-06 Combination Unit (GFC20006NT)
SeriesGFC200 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/8" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC200-06 Combination Unit (GFC20006NT)

GFC200G-series two-unit set, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-06 filter regulator and GL200-06 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC200 · PT1/8" · 40 µm
One size upGFC300
Three-unit equivalentGC200-06
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC200-06 Combination Unit (GFC20006NT) Is Used

handyman

Woodshop nailer and sander drops

In a joinery or furniture shop, each nailer and sander drop gets conditioned air: the 40 um element and regulator protect the tools and hose whip assemblies, and the lubricator mists oil for piston-driven nailers.

conveyor_belt

Bottling line reject and gate actuators

On a bottling line, reject fingers and gate cylinders cycle continuously; this set at the branch line filters, regulates and lubricates the air feeding those small actuators and their valves.

science

Lab pneumatic bench supply

In a laboratory or pilot-plant pneumatic bench, the set conditions the general supply feeding small cylinders and actuators, with the regulator setting a stable bench pressure for experiments.

Is the AirTAC GFC200-06 Combination Unit (GFC20006NT) the Right Set?

This is the base build of the 200-size two-unit set: standard 40 um element, default differential-pressure drain and no gauge - the least specified code in the family. Move to 300, 400 or 600 when the circuit calls for larger ports and more flow than NPT 1/8. Add the W code for the 5 um element where finer filtration is needed, M for a manual drain or A for an automatic drain, and choose a variant with the embedded square gauge or an external round gauge in MPa, psi or bar scale if a pressure readout is required at the set. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. G (BSPP) and NPT are catalogue options. Flow is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.

AirtacDistr lists every GFC200-06 order code with its price on one page at https://airtacdistr.com/products/airtac-gfc200-06-two-unit-frl

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-06 filter regulator on its own.

AirTAC GFC200-06 Combination Unit (GFC20006NT) FAQ

Flow for the G series is published as characteristic curves, not as a single rated figure, so we do not state a number here. Request it and we will confirm the datasheet curve and verify that the 200 size with NPT 1/8 ports suits your application before you order.

N specifies that no gauge is fitted; other codes carry the embedded square gauge or an external round gauge with MPa, psi or bar scale. This code also uses the default differential-pressure drain (no drain letter) and the standard 40 um element; add W for 5 um filtration or M/A for manual or automatic drainage.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC200-06 Combination Unit (GFC20006NT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.