The AirTAC GFC400-15 Combination Unit (GFC40015ANT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC series is a two-unit air-treatment set: a filter-regulator paired with a lubricator, so one assembly removes water and particulate, holds a set downstream pressure and meters oil mist into the air line. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. It is the standard regulator type: with the automatic drain, outlet pressure adjusts over 0.15-0.9 MPa (20-130 psi).
This is a genuine AirTAC part. Maximum working pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing); the size 400 filter bowl is PC (polycarbonate). Across the G series you can step size and port from 200 to 600, choose differential-pressure, automatic or manual drains, order the 5 um (W) element instead of 40 um, add gauge and bracket options and select three thread types (NPT on this code). Flow for this size is published as curves rather than a single rated figure, so we confirm datasheet and sizing values on request. Order code GFC40015ANT has NPT ports (the T in the code) for North American pipe fittings.
| Model | AirTAC GFC400-15 Combination Unit (GFC40015ANT) |
|---|---|
| Series | GFC400 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC400 | G-series two-unit set, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC400 · PT1/2" · 40 µm |
|---|---|
| One size down | GFC300 |
| One size up | GFC600 |
| Three-unit equivalent | GC400-15 |
| Build order | Filter regulator first, lubricator last |
Conditioning plant air for tool-change cylinders, chip augers and air blasts on a vertical machining centre; the 1/2" NPT port matches the machine's main air drop and the automatic drain handles condensate.
Running stopper and gate cylinders on a bottling conveyor; the filter-regulator section keeps the pressure steady over 0.15-0.9 MPa (20-130 psi) while the lubricator mists oil to the cylinder seals.
Supplying a bench-mounted pneumatic press in an electronics assembly cell; the 40 um element guards the control valve and the regulator holds the operator's set pressure through each pressing cycle.
Real choices in this family: step the size and port (200/300/400/600; here 400 with a NPT1/2 port) against the flow your line needs; pick the drain - automatic on this unit, with differential-pressure (default) and manual also available; choose the 40 um standard element or the 5 um (W) option; select thread three thread types (NPT on this code) orderable; and specify a gauge if you want a visual pressure readout, since none is fitted here (MPa, psi or bar scales are orderable). Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
AirtacDistr lists every GFC400-15 order code with its price on one page at https://airtacdistr.com/products/airtac-gfc400-15-two-unit-frl
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.
AirTAC publishes flow for the G series as curves, not as a single rated figure, so we do not quote a number here. Share your line pressure, set pressure and demand and we will confirm the sizing from the datasheet on request.
The N in GFC40015ANT means no gauge is fitted. Units with a regulator can take an embedded square gauge or an optional external round gauge, with MPa, psi or bar scales orderable - tell us the scale you want and we will confirm the option on request.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.