AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC400-15 Combination Unit (GFC40015ANT)

The AirTAC GFC400-15 Combination Unit (GFC40015ANT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 40 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$130.42 $137.92Save 5% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC400-15 drain, gauge and thread option on one page All GFC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC400-15 Combination Unit (GFC40015ANT)

The AirTAC GFC series is a two-unit air-treatment set: a filter-regulator paired with a lubricator, so one assembly removes water and particulate, holds a set downstream pressure and meters oil mist into the air line. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. It is the standard regulator type: with the automatic drain, outlet pressure adjusts over 0.15-0.9 MPa (20-130 psi).

This is a genuine AirTAC part. Maximum working pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing); the size 400 filter bowl is PC (polycarbonate). Across the G series you can step size and port from 200 to 600, choose differential-pressure, automatic or manual drains, order the 5 um (W) element instead of 40 um, add gauge and bracket options and select three thread types (NPT on this code). Flow for this size is published as curves rather than a single rated figure, so we confirm datasheet and sizing values on request. Order code GFC40015ANT has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GFC400-15 Combination Unit (GFC40015ANT) Technical Specifications

ModelAirTAC GFC400-15 Combination Unit (GFC40015ANT)
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC400-15 Combination Unit (GFC40015ANT)

GFC400G-series two-unit set, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT1/2" · 40 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-15
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC400-15 Combination Unit (GFC40015ANT) Is Used

precision_manufacturing

CNC machining centre pneumatics

Conditioning plant air for tool-change cylinders, chip augers and air blasts on a vertical machining centre; the 1/2" NPT port matches the machine's main air drop and the automatic drain handles condensate.

conveyor_belt

Bottling line stopper cylinders

Running stopper and gate cylinders on a bottling conveyor; the filter-regulator section keeps the pressure steady over 0.15-0.9 MPa (20-130 psi) while the lubricator mists oil to the cylinder seals.

engineering

Bench pneumatic press

Supplying a bench-mounted pneumatic press in an electronics assembly cell; the 40 um element guards the control valve and the regulator holds the operator's set pressure through each pressing cycle.

Is the AirTAC GFC400-15 Combination Unit (GFC40015ANT) the Right Set?

Real choices in this family: step the size and port (200/300/400/600; here 400 with a NPT1/2 port) against the flow your line needs; pick the drain - automatic on this unit, with differential-pressure (default) and manual also available; choose the 40 um standard element or the 5 um (W) option; select thread three thread types (NPT on this code) orderable; and specify a gauge if you want a visual pressure readout, since none is fitted here (MPa, psi or bar scales are orderable). Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

AirtacDistr lists every GFC400-15 order code with its price on one page at https://airtacdistr.com/products/airtac-gfc400-15-two-unit-frl

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.

AirTAC GFC400-15 Combination Unit (GFC40015ANT) FAQ

AirTAC publishes flow for the G series as curves, not as a single rated figure, so we do not quote a number here. Share your line pressure, set pressure and demand and we will confirm the sizing from the datasheet on request.

The N in GFC40015ANT means no gauge is fitted. Units with a regulator can take an embedded square gauge or an optional external round gauge, with MPa, psi or bar scales orderable - tell us the scale you want and we will confirm the option on request.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC400-15 Combination Unit (GFC40015ANT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.