The AirTAC GAC F.R.L. Unit GAC300C10ALNT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. The metal bowl equips this 3/8in ported assembly, which regulates pressure within a 0.15-0.4 MPa (20-58 psi) range using a 40 um element.
Because no gauge is supplied, operators must use the 1/8in gauge connection to add instrumentation for reading the set pressure. The automatic drain clears condensate from the 60 cc bowl without manual intervention, while the 98 cc oil reservoir feeds an ISO VG 32 mist downstream of the regulator seat. Order code GAC300C10ALNT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300C10ALNT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds air to loom and spinning frame actuators that require consistent low-pressure operation and continuous oil mist for fast-moving guide rails.
Prepares supply for sealing jaws and film feed clamps, where the automatic drain handles moisture from high-duty cycling without halting the line.
Conditions air for pick-and-place units and small pneumatic grippers, providing stable low-pressure control and lubrication for cylinder seals.
Choose this lower-pressure type when the machine strictly operates under 0.4 MPa, as it cannot satisfy higher output demands. The metal bowl suits harsher industrial environments, and the automatic drain keeps the 60 cc condensate sump empty during unattended shifts. If the downstream line must remain completely free of oil, select a filter-regulator instead of this lubricator-equipped assembly. Replacement spares follow the same body and port suffix, utilizing GAF300-10, GAR300-10 and GAL300-10 components. The 0.4 MPa ceiling is 44% of the 0.9 MPa limit found on standard variants, defining the operational tradeoff for this model.
AirtacDistr lists every GAC300-10 order code with its price on one page at https://airtacdistr.com/products/airtac-gac300-10-three-unit-frl
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This model operates at 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It features a 60 cc drain bowl, a 98 cc oil bowl, a 40 um element, weighs 1300 g, and uses ISO VG 32 lubricant.
The N in the model code indicates no gauge is supplied from the factory. The bracket features a 1/8in gauge connection, allowing you to install a compatible pressure measuring instrument separately to monitor the 0.15-0.4 MPa operating range.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.