The AirTAC GAC F.R.L. Unit GAC300C10ASNT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for pneumatic systems, this GAC300C10ASNT is a complete three-unit F.R.L. combination pre-plumbed on a single L-shape bracket. The 3/8in port pairs with a standard pressure range of 0.15-0.9 MPa (20-130 psi) and a 40 um element. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling during pressure modulation.
This specific configuration uses a durable metal bowl and an automatic drain that expels condensate without an operator, making it well-suited for wet lines or unattended machinery. The 60 cc drain bowl and 98 cc oil reservoir dictate the maintenance interval, requiring fewer interventions than smaller bodies. No gauge is supplied, but a 1/8in gauge connection allows operators to add instrumentation for reading the set pressure. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300C10ASNT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds clean, lubricated air at a stable pressure to multi-station assembly machinery where the automatic drain handles condensate during continuous shifts.
Conditions air for high-cycle packaging actuators, utilizing the 3/8in port and 40 um filtration to protect directional valves from particulate ingress.
Supplies metered oil mist to moving parts on sorting conveyors, with the metal bowl providing durability in active production zones.
Choose this metal-bowl unit for rugged environments where a standard PC bowl might risk impact damage, relying on the automatic drain to clear the 60 cc condensate sump autonomously. If your downstream line must remain oil-free, omit the lubricator and select a standalone filter-regulator instead. Because no gauge is included, you will need to add one to the 1/8in port to verify settings, and the NPT thread dictates a MPa/psi scale. For maintenance, the assembly accepts individual GAF300-10, GAR300-10 and GAL300-10 replacement parts. Stepping up to the GAC400 body raises the plotted flow envelope from 3000 L/min to 6000 L/min at 0.7 MPa inlet, doubling the capacity. Note that the 1.5 MPa (215 psi) proof pressure provides a 1.5x burst-test margin over the 1.0 MPa maximum, which is not permission to run above 1.0 MPa.
AirtacDistr lists every GAC300-10 order code with its price on one page at https://airtacdistr.com/products/airtac-gac300-10-three-unit-frl
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This unit operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It handles temperatures from -5 to 70 C, features a 40 um element, and uses ISO VG 32 lubricant. The drain bowl holds 60 cc, the oil bowl holds 98 cc, and the unit weighs 1300 g.
No, the N in the code indicates no gauge is supplied. However, the body features a 1/8in gauge connection, allowing you to install a separate instrument to monitor the regulated pressure.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.