The AirTAC GAC F.R.L. Unit GAC300C10LNTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air, this AirTAC assembly integrates a filter, regulator and lubricator on a single L-shape bracket. The 3/8in port pairs with a 1300 g mass, placing it firmly in the mid-size class for panel mounting rather than tubing support. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling during pressure control.
This variant features a robust metal bowl and operates on the lower pressure scale at 0.15-0.4 MPa (20-58 psi). It ships without a gauge, though a 1/8in connection is provided to add one. The reverse-flow (reflux) valve is fitted, shown as a separate pneumatic symbol in the catalogue, and the standard 40 um element captures general moisture and solid grain. Order code GAC300C10LNTK has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300C10LNTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds sensitive 3/8in actuated clamping jigs on machining fixtures where pressure must stay strictly under 0.4 MPa to prevent workpiece deformation.
Conditions air for low-pressure heat-sealing equipment, adding the exact oil mist required by moving guide rails while filtering out 40 um particulates.
Supplies regulated air to benchtop pneumatic test stands, utilizing the metal bowl for solvent resistance in varied analytical environments.
Choose this configuration when a 3/8in line requires strict low-pressure control up to 0.4 MPa, paired with a durable metal bowl for harsh surroundings. The semi-auto and manual drain pair handles condensate removal where an operator is present, unlike the automatic drain option. If the downstream process requires completely oil-free air, omit the lubricator and select a standalone filter-regulator instead. For maintenance, the three units are separately orderable as GAF300-10, GAR300-10 and GAL300-10.
Stepping up to the GAC400 body raises the condensate bowl from 60 cc to 100 cc and extends the plotted flow curve to 6000 L/min at 0.7 MPa inlet, compared to the 3000 L/min envelope of this GAC300. Remember that the 0.4 MPa ceiling is 44% of the standard 0.9 MPa upper limit, so verify your machinery never requires higher operating pressure.
AirtacDistr lists every GAC300-10 order code with its price on one page at https://airtacdistr.com/products/airtac-gac300-10-three-unit-frl
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure type unit regulates from 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 1300 g, and features a 60 cc drain bowl with a 98 cc oil bowl. The recommended lubricant is ISO VG 32.
The N in the ordering code indicates no gauge is supplied. The body features a 1/8in gauge connection, allowing operators to install a separate gauge reading in MPa/psi to match the default NPT thread and monitor the 0.15-0.4 MPa range.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.