The AirTAC GAC F.R.L. Unit GAC300N10SNW is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for pneumatic systems, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. It features a 3/8in port, a standard pressure range of 0.15-0.9 MPa (20-130 psi), and a 5 um element for trapping fine particles. The nylon bowl equips this assembly for environments where material compatibility is prioritized.
Air passes through the filter first, then the regulator, before oil mist is introduced downstream by the lubricator so the regulator seat never gets fouled. Because the code includes an N after the port, no pressure gauge is supplied; you can add one via the 1/8in gauge connection. The 60 cc condensate bowl and 98 cc oil bowl dictate the maintenance frequency for this 1300 g assembly.
| Model | Airtac GAC F.R.L. Unit GAC300N10SNW |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds precision valves on a CNC machining center where the 5 um element protects sensitive tool-changer actuators from fine particulate ingress.
Conditions air for a vertical form-fill-seal machine, supplying steady 0.15-0.9 MPa pressure to the film pulling cylinders while the lubricator extends their seal life.
Prepares air for laboratory analytical equipment, using the nylon bowl to avoid chemical reactivity while the 3/8in port handles intermittent actuator demand.
Choose this 3/8in body when your machine demands finer filtration than the standard 40 um grade, as the 5 um element suits precision valves and instrument air at the cost of more frequent element service. It carries a semi-auto and manual drain pair, meaning the semi-auto dumps condensate on each pressure drop while the manual option allows on-demand emptying. If your downstream line must remain strictly oil-free, you should omit the lubricator and choose a filter-regulator instead. Replacement parts are available separately as GAF300-10, GAR300-10 and GAL300-10. Stepping up to the GAC400 roughly doubles the flow envelope, plotting to 6000 L/min at 0.7 MPa inlet compared to this body's 3000 L/min curve, making the larger unit better for high-demand lines. The 1.5 MPa proof pressure against the 1.0 MPa maximum provides a 1.5x burst-test margin, which is not permission to run above the 1.0 MPa limit.
AirtacDistr lists every GAC300-10 order code with its price on one page at https://airtacdistr.com/products/airtac-gac300-10-three-unit-frl
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type F.R.L. combination operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It has a 3/8in port, a 5 um element, a 60 cc drain bowl, a 98 cc oil bowl, and weighs 1300 g. The operating temperature is -5 to 70 C, and the recommended lubricant is ISO VG 32.
The N in the model code after the port indicates no gauge is supplied. To read the set pressure, you must install a circular gauge into the 1/8in gauge connection on the body, matching the MPa/psi scale for the default PT thread.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.