The AirTAC GAC F.R.L. Unit GAC400C10LNW is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, lubricated and precisely set air for downstream pneumatics, this GAC400C10LNW assembly integrates a filter, regulator and lubricator on a single L-shape bracket. The 3/8in port pairs with a 5 um element to capture fine particulates before they reach sensitive valves. Because the metal bowl equips this unit, it suits rugged plant environments where polycarbonate might not be permitted.
This lower-pressure type regulates between 0.15-0.4 MPa (20-58 psi), making it suitable for low-force actuator circuits. No gauge is supplied, but the body features a 1/4in gauge connection for adding instrumentation later. The 100 cc condensate sump and 185 cc oil reservoir reduce maintenance frequency compared to smaller bodies, while the semi-auto and manual drain pair clears accumulated water reliably.
| Model | Airtac GAC F.R.L. Unit GAC400C10LNW |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC400 is 1/4" if you add one.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds delicate pneumatic grippers on electronics assembly lines where the 0.15-0.4 MPa range prevents crushing fragile components.
Conditions supply air for benchtop analytical instruments, relying on the 5 um element to protect sensitive flow controllers from fine grit.
Supplies a steady, oil-misted air supply to small actuators on packaging equipment, utilizing the metal bowl for shop-floor longevity.
Choose this 2390 g unit when a machine requires very fine 5 um filtration alongside a low 0.15-0.4 MPa (20-58 psi) operating band. The metal bowl offers durability for industrial settings, and the missing gauge means you must add one to the 1/4in port to read set pressure. If the application requires downstream air to remain completely free of oil, omit the lubricator and select a standalone filter-regulator instead. For maintenance, the individual elements and bowls are orderable separately as GAF400-10, GAR400-10 and GAL400-10. Stepping up from the GAC300 roughly doubles the available flow capacity, as the catalogue curve for this body is plotted to 6000 L/min at 0.7 MPa inlet versus 3000 L/min for the smaller neighbour. Keep in mind that 0.4 MPa is 44% of the standard 0.9 MPa ceiling.
AirtacDistr lists every GAC400-10 order code with its price on one page at https://airtacdistr.com/products/airtac-gac400-10-three-unit-frl
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates in temperatures from -5 to 70 C, features a 100 cc drain bowl and a 185 cc oil bowl, weighs 2390 g, and uses ISO VG 32 lubricant.
The N in the ordering code denotes that no circular gauge is supplied from the factory. To monitor the 0.15-0.4 MPa outlet setting, operators must fit a separate gauge into the 1/4in connection port on the regulator body.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.