AirTAC GAC400 · F.R.L. Combination (Filter + Regulator + Lubricator)

Airtac GAC F.R.L. Unit GAC400C10LWK

The AirTAC Airtac GAC F.R.L. Unit GAC400C10LWK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size3/8"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade5 µm
  • Bowl materialMetal
  • Drainsemi-auto + manual
  • Pressure gaugeCircular, MPa / psi
  • Weight2390 g
$139.76 $152.88Save 8% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAC F.R.L. Unit GAC400C10LWK

Delivering cleaned, regulated and lubricated air for pneumatic systems, this GAC400C10LWK combines a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 3/8in port pairs with a 5 um element to trap fine particles before they reach sensitive valves. Because the lubricator sits downstream of the regulator, oil mist is added last, preventing fouling of the regulating seat.

This variant features a robust metal bowl and operates on the lower pressure range of 0.15-0.4 MPa (20-58 psi). A circular gauge reading MPa/psi is fitted for the default PT thread, allowing operators to monitor the set pressure directly. The reverse-flow (reflux) valve is fitted, shown as a separate pneumatic symbol in the catalogue, and the 100 cc drain bowl paired with a 185 cc oil bowl dictates the maintenance interval.

Airtac GAC F.R.L. Unit GAC400C10LWK Technical Specifications

ModelAirtac GAC F.R.L. Unit GAC400C10LWK
SeriesGAC400 F.R.L. combination
Port size3/8" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialMetal
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight2390 g

Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAC F.R.L. Unit GAC400C10LWK

GAC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
CBowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N).
10Port size 3/8". This body offers 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.

Size Class & Flow Envelope

  • GAC2001/8"-1/4" · 1750 L/min
  • GAC3001/4"-1/2" · 3000 L/min
  • GAC4003/8"-1/2" · 6000 L/min
  • GAC5003/4" · 7000 L/min
  • GAC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAC400 · 3/8" · curve to 6000 L/min
One size downGAC300
One size upGAC500 (curve to 7000 L/min)
Build orderFilter → bracket → regulator → lubricator

Where the Airtac GAC F.R.L. Unit GAC400C10LWK Is Used

precision_manufacturing

Precision Valve Arrays

Feeds clean, finely filtered 5 um air to low-pressure pneumatic valve manifolds in coordinate measuring machines where standard 40 um filtration is insufficient.

packaging

Low-Pressure Packaging

Supplies steady 0.15-0.4 MPa lubricated air to delicate sealing jaws and clamping actuators in flow-wrapping equipment to prevent delicate film tearing.

science

Laboratory Pneumatics

Conditions air for sensitive laboratory dosing pumps and fluid handling actuators that require stable low-pressure operation and consistent oil mist delivery.

Is the Airtac GAC F.R.L. Unit GAC400C10LWK the Right Air-Prep Unit?

Choose this 2390 g unit for medium-duty air preparation requiring fine filtration and low-pressure regulation. The 5 um element provides higher purity than the standard 40 um grade, ideal for instrument air, though it requires more frequent element replacement. The metal bowl suits harsher industrial environments, while the semi-auto and manual drain options give operators flexibility in condensate management. If the downstream line must remain completely oil-free, omit the lubricator and select a filter-regulator instead. Replacement spares follow the body-port suffix exactly: GAF400-10, GAR400-10 and GAL400-10.

When sizing, the catalogue flow curve for the GAC400 is plotted to 6000 L/min at 0.7 MPa inlet, exactly double the 3000 L/min envelope of the GAC300. Keep in mind that the 0.4 MPa ceiling is 44% of the Standard type's 0.9 MPa maximum, so verify your machinery never requires a higher operating pressure before specifying this L-type unit.

Quick checklist

  • ✓ Body size for your peak flow (3/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 2390 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.

Airtac GAC F.R.L. Unit GAC400C10LWK FAQ

This lower-pressure type unit regulates from 0.15-0.4 MPa (20-58 psi) and carries a max pressure of 1.0 MPa (145 psi) with a 1.5 MPa (215 psi) proof pressure. Operating temperature is -5 to 70 C using ISO VG 32 lubricant. It features a 3/8in port, a 100 cc drain bowl, a 185 cc oil bowl, and weighs 2390 g.

The K indicates that a reverse-flow (reflux) valve is attached to the assembly. The official AirTAC catalogue displays this as a distinct pneumatic symbol located on its own dedicated page, and specific functional details should be confirmed from that datasheet.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAC F.R.L. Unit GAC400C10LWK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAC400C10LWK and will confirm price, stock and lead time — usually within 7-8 hours.