The AirTAC Airtac GAC F.R.L. Unit GAC400N10LNW is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. It features a 3/8in port, a 5 um element and a nylon bowl. The lower-pressure type restricts the operating range to 0.15-0.4 MPa (20-58 psi). Air passes through the filter first, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls.
Weighing 2390 g, this assembly needs a proper panel or frame mount rather than support from the tubing. It carries a 100 cc condensate bowl and a 185 cc oil reservoir. Because the code includes an N after the port, no pressure gauge is supplied; the 1/4in gauge connection is available if you need to add one later. The 5 um element traps far finer particles than the standard 40 um grade, making it suitable for precision valves, though it requires more frequent service.
| Model | Airtac GAC F.R.L. Unit GAC400N10LNW |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC400 is 1/4" if you add one.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds sensitive directional valves in a machining center using the 5 um element to prevent sticking, while the lower 0.4 MPa pressure protects delicate internal seals.
Conditions air for packaging equipment where light gripping forces are required, adding a controlled oil mist to lubricate the small gripper cylinders.
Supplies clean, regulated air to test fixtures and actuator arrays, relying on the 100 cc drain bowl to capture moisture from intermittent duty cycles.
Choose this lower-pressure type if your machine operates strictly within 0.15-0.4 MPa (20-58 psi); if the application may ever need more, the L type is the wrong part. The semi-auto and manual drain pair is fitted, dumping condensate on each pressure drop or on demand. If the line must stay oil-free, omit the lubricator and choose a filter-regulator instead. For maintenance, the three units are separately orderable as GAF400-10, GAR400-10 and GAL400-10, so a clogged element does not require replacing the whole assembly. The catalogue flow curve for the GAC400 is plotted to 6000 L/min at 0.7 MPa inlet, which is 200% of the GAC300's 3000 L/min envelope. Note that the 0.4 MPa ceiling is 44% of the Standard type's 0.9 MPa maximum.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This unit operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It features a 100 cc drain bowl and a 185 cc oil bowl, uses ISO VG 32 lubricant, and weighs 2390 g.
The N in the ordering code indicates no gauge is supplied. The body has a 1/4in gauge connection, allowing you to install a separate gauge reading MPa/psi for the default PT thread if you need to monitor the set pressure.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.