The AirTAC Airtac GAC F.R.L. Unit GAC400N10LW is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for pneumatic systems, this AirTAC unit integrates a filter, regulator and lubricator on a single L-shape bracket. The 3/8in ported body houses a 5 um element for trapping fine particles, while the lower pressure type governs output strictly between 0.15-0.4 MPa (20-58 psi). A circular gauge is fitted, reading MPa/psi for the default PT thread.
Air passes through the filter first, then the regulator, ensuring oil mist from the lubricator is added last so it never fouls the regulator seat. The nylon bowl equips this assembly with a 100 cc condensate capacity and a 185 cc oil reservoir, requiring panel mounting to support its 2390 g mass. Condensate is expelled via a semi-auto and manual drain combination.
| Model | Airtac GAC F.R.L. Unit GAC400N10LW |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds instrument-quality air to sensitive solenoid valve banks using the 5 um element to prevent spool sticking.
Regulates low-pressure air for delicate test fixtures that require stable 0.15-0.4 MPa outputs without risking over-pressurization.
Conditions air for small pick-and-place actuators, adding the exact oil mist needed to prolong cylinder seals.
Choose this configuration when a 3/8in line requires precision filtration and low outlet pressures. The 5 um element catches far finer particulates than the standard 40 um grade, making it ideal for sensitive valves, though it will require more frequent element replacement. If the machinery might ever demand more than 0.4 MPa, the L type is the wrong choice, as it caps out well below the standard 0.9 MPa ceiling. Because oil mist is injected downstream, select a filter-regulator instead if the application requires strictly oil-free air downstream. Replacement parts share the same body-port suffix: order GAF400-10, GAR400-10 and GAL400-10 individually. Stepping down to the GAC300 halves the plotted flow envelope to 3000 L/min at 0.7 MPa inlet, whereas this 400 body reaches 6000 L/min. The 0.4 MPa upper limit of this lower-pressure type is just 44% of the standard 0.9 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure type regulates from 0.15-0.4 MPa (20-58 psi). It shares a 1.0 MPa (145 psi) maximum pressure and a 1.5 MPa (215 psi) proof pressure across the series. Operating temperature is -5 to 70 C, using ISO VG 32 lubricant. The unit weighs 2390 g, features a 100 cc drain bowl and a 185 cc oil bowl.
The nylon bowl provides a durable, shatter-resistant alternative to standard PC without changing the 1.0 MPa pressure rating. The fitted semi-auto drain expels condensate automatically whenever the system pressure drops, but also includes a manual override for on-demand emptying between cycles.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.