verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAC400 · F.R.L. Combination (Filter + Regulator + Lubricator)

Airtac GAC F.R.L. Unit GAC400N10SK

The AirTAC Airtac GAC F.R.L. Unit GAC400N10SK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination
  • Port size3/8"
  • Pressure range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • Bowl materialNylon
  • Drainsemi-auto + manual
  • Pressure gaugeCircular, MPa / psi
  • Weight2390 g
$139.76 $152.88Save 8% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAC F.R.L. Unit GAC400N10SK

Delivering cleaned, regulated and lubricated air for mid-sized pneumatics, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. The 3/8in ported body operates at 0.15-0.9 MPa (20-130 psi) and uses a 40 um element. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling during pressure modulation.

The assembly features a nylon bowl and includes a reverse-flow (reflux) valve, which the catalogue illustrates as a separate pneumatic symbol. A circular gauge is fitted, reading MPa/psi for the default PT thread. Weighing 2390 g, the unit needs a solid panel or frame mount rather than tubing support, and its 100 cc condensate bowl paired with a 185 cc oil reservoir sets the maintenance interval.

Airtac GAC F.R.L. Unit GAC400N10SK Technical Specifications

ModelAirtac GAC F.R.L. Unit GAC400N10SK
SeriesGAC400 F.R.L. combination
Port size3/8" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.9 MPa (20 - 130 psi)
TypeStandard
Bowl materialNylon
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl100 cc
Capacity of oil bowl185 cc
Recommended lubricantISO VG 32 or equivalent
Weight2390 g

Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAC F.R.L. Unit GAC400N10SK

GAC400GA400 series F.R.L. unit — sets ports, bowl capacity and weight.
NBowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N).
10Port size 3/8". This body offers 10 = 3/8", 15 = 1/2".
(blank)Drain: Semi-auto drain + manual drain.
SStandard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.

Size Class & Flow Envelope

  • GAC2001/8"-1/4" · 1750 L/min
  • GAC3001/4"-1/2" · 3000 L/min
  • GAC4003/8"-1/2" · 6000 L/min
  • GAC5003/4" · 7000 L/min
  • GAC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAC400 · 3/8" · curve to 6000 L/min
One size downGAC300
One size upGAC500 (curve to 7000 L/min)
Build orderFilter → bracket → regulator → lubricator

Where the Airtac GAC F.R.L. Unit GAC400N10SK Is Used

factory

Automated Assembly Lines

Feeds main air headers for multi-station assembly machinery where a 3/8in port provides adequate flow to several actuators.

packaging

Carton Sealing Equipment

Conditions air for continuous motion packaging conveyors, ensuring pneumatic folding arms receive steady pressure and oil mist.

straighten

Metal Forming Presses

Supplies regulated air to pneumatic clamps and ejection cylinders on small to mid-sized forming presses.

Is the Airtac GAC F.R.L. Unit GAC400N10SK the Right Air-Prep Unit?

Choose this GAC400 configuration for duties requiring a standard pressure range and a manual condensate routine, as it ships with both semi-auto and manual drains fitted. The 40 um element suits general plant air, while the nylon bowl offers a non-metallic housing option within the shared -5 to 70 C temperature limit. If your downstream line must remain completely oil-free, omit the lubricator and select a dedicated filter-regulator instead. For maintenance, the individual elements are separately orderable as GAF400-10, GAR400-10 and GAL400-10.

Stepping down, the GAC300 flow curve is plotted to 3000 L/min at 0.7 MPa inlet, whereas this GAC400 body is plotted to 6000 L/min, effectively doubling the available sizing envelope. When sizing the supply, remember the 1.0 MPa maximum inlet leaves only about 0.1 MPa of headroom above the 0.9 MPa standard setting.

Quick checklist

  • ✓ Body size for your peak flow (3/8" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 100 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 2390 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.

Airtac GAC F.R.L. Unit GAC400N10SK FAQ

This model operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It features a 100 cc drain bowl, a 185 cc oil bowl, and weighs 2390 g. The recommended lubricant is ISO VG 32.

The K indicates that a reverse-flow (reflux) valve is attached to the unit. The catalogue shows this component as a distinct pneumatic symbol, and specific operational details for the valve should be confirmed from its dedicated datasheet page.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAC F.R.L. Unit GAC400N10SK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAC400N10SK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.