The AirTAC Airtac GAC F.R.L. Unit GAC400N10SN is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air, this AirTAC GAC400N10SN assembly integrates a filter, regulator and lubricator on a single L-shape bracket with quick clamps. It features a 3/8in port, a 40 um element and a standard pressure range of 0.15-0.9 MPa (20-130 psi). The nylon bowl equips this unit for environments where polymer transparency is preferred, while the build order ensures oil mist is added downstream of the regulator so the internal seat never fouls.
Because the code carries an N after the port, no pressure gauge is supplied; you can add one via the 1/4in gauge connection. Weighing 2390 g, this body demands a solid panel or frame mount rather than tubing support. It ships with both a semi-auto drain that dumps condensate on every pressure drop and a manual drain for on-demand emptying into the 100 cc bowl.
| Model | Airtac GAC F.R.L. Unit GAC400N10SN |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC400 is 1/4" if you add one.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds pneumatic impact wrenches and actuators on a vehicle production track, supplying steady 0.6 MPa pressure and oil mist for high-cycle tooling.
Prepares air for the folding cylinders and vacuum cups on a high-speed packaging line, trapping 40 um particulates before they reach the valves.
Conditions air for rapid pneumatic pushers on a logistics conveyor, relying on the 100 cc condensate bowl to capture moisture from continuous duty.
This 3/8in port model suits mid-scale pneumatic duties, plotting a flow envelope to 6000 L/min at 0.7 MPa inlet, which is double the GAC300's 3000 L/min capacity. The 40 um element handles general plant air, whereas the 5 um W option targets precision instrumentation. If your line must remain oil-free, omit the lubricator and choose a separate filter-regulator instead. For maintenance, the assembly accepts GAF400-10, GAR400-10 and GAL400-10 replacement units. The 1.5 MPa (215 psi) proof pressure provides a 1.5x burst-test margin over the 1.0 MPa maximum, confirming structural safety without permitting operation above the rated ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 2390 g, holds 100 cc of condensate and 185 cc of oil, and uses ISO VG 32 lubricant.
The N after the port code means no gauge is supplied from the factory. You can install your own circular gauge in the 1/4in threaded connection, reading MPa/psi for the default PT thread, to verify the downstream setpoint.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.