The AirTAC Airtac GAC F.R.L. Unit GAC400N10SNWK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for mid-size pneumatics, this AirTAC F.R.L. combination pre-assembles a filter, regulator and lubricator on a single L-shape bracket. The 3/8in port serves a 2390 g unit that conditions supply within a 0.15-0.9 MPa (20-130 psi) standard pressure range. A 5 um element captures fine particulates, while the nylon bowl equips the assembly without a fitted pressure gauge.
Air routing strictly follows filter, regulator and lubricator stages, so oil mist is introduced downstream of the regulator seat. Condensate accumulates in a 100 cc bowl and lubricant in a 185 cc reservoir, dictating the maintenance interval. The reverse-flow (reflux) valve is fitted, appearing as a separate pneumatic symbol in the catalogue.
| Model | Airtac GAC F.R.L. Unit GAC400N10SNWK |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC400 is 1/4" if you add one.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds multiple pneumatic presses and actuators on a car manufacturing line, relying on the 5 um element to protect precision valves from fine particulates.
Conditions air for continuous packaging conveyors where the 100 cc condensate bowl and semi-auto drain handle moisture from high-cycle actuator duty.
Supplies regulated, oil-misted air to instrument panels, requiring the operator to add a gauge to the 1/4in connection to verify the 0.15-0.9 MPa setpoint.
Choose this 3/8in body for mid-capacity duties, stepping up from the GAC300 which offers a 3000 L/min plotted flow envelope at 0.7 MPa inlet versus the 6000 L/min curve of this GAC400. The nylon bowl keeps the standard 1.0 MPa (145 psi) maximum and -5 to 70 C temperature limits, requiring chemical compatibility confirmation for aggressive surroundings. Since no gauge is supplied, the set pressure cannot be read without adding one to the 1/4in gauge connection. If the downstream line must stay oil-free, omit the lubricator and choose a filter-regulator instead. Replacement spares share the 400-10 suffix: GAF400-10, GAR400-10 and GAL400-10. Stepping from the GAC300 to this GAC400 doubles the flow envelope, providing exactly a 2x sizing multiplier at 0.7 MPa inlet.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It functions from -5 to 70 C, weighs 2390 g, holds 100 cc of condensate and 185 cc of oil, and uses ISO VG 32 lubricant.
The N in the ordering code signifies no gauge is supplied. The unit features a 1/4in gauge connection, allowing operators to install a separate PT-threaded gauge reading MPa/psi to monitor the 5 um filtered output.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.