AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-08 FRL Unit (GC20008C2T)

The AirTAC GC200-08 FRL Unit (GC20008C2T) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$71.65 $79.15Save 9% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-08 FRL Unit (GC20008C2T)

The AirTAC GC series is a three-unit F.R.L. combination: a separate air filter, a pressure regulator and a lubricator, covering filtration, regulation and oil-mist lubrication in one set. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes.

This is a genuine AirTAC part. The G series runs from size 200 to 600 with ports up to 1 inch and thread options three thread types (NPT on this code). Maximum working pressure is 1.0 MPa (145 psi), temperature range is -5 to 70 C (non-freezing), and the regulator set range on this differential-drain version is 0.15-0.9 MPa (20-130 psi). Because flow is published as curves and not as a single rated figure, we confirm sizing and datasheet details on request. Order code GC20008C2T has NPT ports (the T in the code) for North American pipe fittings.

AirTAC GC200-08 FRL Unit (GC20008C2T) Technical Specifications

ModelAirTAC GC200-08 FRL Unit (GC20008C2T)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-08 FRL Unit (GC20008C2T)

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 40 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-08 FRL Unit (GC20008C2T) Is Used

factory

Carton sealing machine air

Filtered, regulated and lubricated supply for the cylinders and actuators of a carton sealer on a packaging line, with the psi gauge readable by US-based operators.

handyman

Impact wrench station in a maintenance shop

A bench-side FRL for pneumatic impact wrenches and ratchets, where the lubricator keeps tool motors oiled during daily shop use.

conveyor_belt

Air cylinders on a conveyor diverter

Supply conditioning for pusher and diverter cylinders along a conveyor line, giving one filtered, regulated and lubricated feed for several small actuators.

Is the AirTAC GC200-08 FRL Unit (GC20008C2T) the Right Station?

Size 200 carries 1/4 inch ports and is the compact step of the G series; larger sizes (300, 400, 600) add port and flow capability. The differential-pressure drain is the default; choose the A suffix for automatic drain or M for manual drain, which widens the regulator range to 0.05-0.9 MPa (7-130 psi). The 40 um element is the standard filtration grade, with the 5 um W option available.

The C2 gauge code here is the external round gauge with psi scale; MPa and bar scales are catalogue options. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow for this family is published as curves rather than a single rating, so ask us to confirm sizing before ordering.

AirtacDistr lists every GC200-08 order code with its price on one page at https://airtacdistr.com/products/airtac-gc200-08-three-unit-frl

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

AirTAC GC200-08 FRL Unit (GC20008C2T) FAQ

Flow for this family is published as curves, not as a single rated figure, so we do not state one number here. Send us your application details and we will confirm the flow curve and datasheet figures before you order.

The C2 code selects the external round gauge with a psi scale, a natural fit for US reading. MPa (C1) and bar (C3) scale gauges are also catalogue options on the same unit.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-08 FRL Unit (GC20008C2T)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.