verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC200-08 FRL Unit (GC20008NWTK)

The AirTAC GC200-08 FRL Unit (GC20008NWTK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$78.78 $86.28Save 8% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC200-08 drain, gauge and thread option on one page All GC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC200-08 FRL Unit (GC20008NWTK)

The AirTAC GC series is a three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator mounted as one set, covering filtration, regulation and oil-mist lubrication from one connection. This GC20008NWTK is the 200 size with 1/4 in NPT ports, the fine 5 um filter element (W code) and a differential-pressure drain, and the regulator carries a reverse/check valve (K code) that holds downstream pressure if the upstream supply fails. No gauge is fitted (N code). Maximum inlet pressure is 1.0 MPa (145 psi), and with the differential-pressure drain the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi). Operating temperature is -5 to 70 C (non-freezing).

This is a genuine AirTAC part from the G series, which spans 200 to 600 sizes with ports from 1/8 in to 1 in. Filter grade (40 um standard, 5 um optional), drain type, gauge and scale, thread (NPT on this code) and bracket choices are all selectable. Flow is published as curves rather than a single rating, so we confirm datasheet and sizing figures for your application on request.

AirTAC GC200-08 FRL Unit (GC20008NWTK) Technical Specifications

ModelAirTAC GC200-08 FRL Unit (GC20008NWTK)
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC200-08 FRL Unit (GC20008NWTK)

GC200G-series F.R.L. combination, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · PT1/4" · 5 µm
One size upGC300
Two-unit equivalentGFC200-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC200-08 FRL Unit (GC20008NWTK) Is Used

shield

Load-holding vertical cylinder circuits

Feeds vertically acting cylinders on a lifting or pressing station, where the check valve helps hold the downstream pressure setting if the plant air supply is interrupted.

precision_manufacturing

Robotic gripper cell

Supplies the grippers and small actuators on a robotic pick-and-place cell, with 5 um filtered, regulated, lubricated air suited to closely toleranced gripper valves.

engineering

Pneumatic test rigs and jigs

Conditions air on a workshop test jig where a set pressure must stay stable downstream: the regulator fixes the setting and the check valve guards it against supply-side dips.

Is the AirTAC GC200-08 FRL Unit (GC20008NWTK) the Right Station?

The 200 frame with 1/4 in NPT ports is the compact step of the G series; step up to GC300, GC400 or GC600 with 3/8 in to 1 in ports for higher demand. Here the W code gives the 5 um element instead of the standard 40 um, and the K code adds the reverse/check valve - useful wherever a dropped supply must not unload the circuit; order without K if that is not needed. Drain is differential-pressure and no gauge is fitted; gauged codes with MPa, psi or bar scales are available. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.

AirtacDistr lists every GC200-08 order code with its price on one page at https://airtacdistr.com/products/airtac-gc200-08-three-unit-frl

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.

AirTAC GC200-08 FRL Unit (GC20008NWTK) FAQ

Flow for the GC series is published as characteristic curves rather than one rated figure, so there is no single number to quote. Give us your working pressure and demand and we will confirm the datasheet figures and the right size on request before you order.

K means a reverse/check valve is fitted at the regulator, holding downstream pressure if the upstream supply drops. It is chosen for circuits where a lost supply must not unload the setting; order the code without K when backflow holding is not required.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC200-08 FRL Unit (GC20008NWTK)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.