The AirTAC GC200-08 FRL Unit (GC20008NWTK) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC series is a three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator mounted as one set, covering filtration, regulation and oil-mist lubrication from one connection. This GC20008NWTK is the 200 size with 1/4 in NPT ports, the fine 5 um filter element (W code) and a differential-pressure drain, and the regulator carries a reverse/check valve (K code) that holds downstream pressure if the upstream supply fails. No gauge is fitted (N code). Maximum inlet pressure is 1.0 MPa (145 psi), and with the differential-pressure drain the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi). Operating temperature is -5 to 70 C (non-freezing).
This is a genuine AirTAC part from the G series, which spans 200 to 600 sizes with ports from 1/8 in to 1 in. Filter grade (40 um standard, 5 um optional), drain type, gauge and scale, thread (NPT on this code) and bracket choices are all selectable. Flow is published as curves rather than a single rating, so we confirm datasheet and sizing figures for your application on request.
| Model | AirTAC GC200-08 FRL Unit (GC20008NWTK) |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-08 filter, GR200-08 regulator and GL200-08 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · PT1/4" · 5 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-08 |
| Build order | Filter → regulator → lubricator |
Feeds vertically acting cylinders on a lifting or pressing station, where the check valve helps hold the downstream pressure setting if the plant air supply is interrupted.
Supplies the grippers and small actuators on a robotic pick-and-place cell, with 5 um filtered, regulated, lubricated air suited to closely toleranced gripper valves.
Conditions air on a workshop test jig where a set pressure must stay stable downstream: the regulator fixes the setting and the check valve guards it against supply-side dips.
The 200 frame with 1/4 in NPT ports is the compact step of the G series; step up to GC300, GC400 or GC600 with 3/8 in to 1 in ports for higher demand. Here the W code gives the 5 um element instead of the standard 40 um, and the K code adds the reverse/check valve - useful wherever a dropped supply must not unload the circuit; order without K if that is not needed. Drain is differential-pressure and no gauge is fitted; gauged codes with MPa, psi or bar scales are available. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.
AirtacDistr lists every GC200-08 order code with its price on one page at https://airtacdistr.com/products/airtac-gc200-08-three-unit-frl
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-08 regulator with a GF200-08 filter on that branch.
Flow for the GC series is published as characteristic curves rather than one rated figure, so there is no single number to quote. Give us your working pressure and demand and we will confirm the datasheet figures and the right size on request before you order.
K means a reverse/check valve is fitted at the regulator, holding downstream pressure if the upstream supply drops. It is chosen for circuits where a lost supply must not unload the setting; order the code without K when backflow holding is not required.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.