verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC300 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC300-08 FRL Unit (GC30008LNT)

The AirTAC GC300-08 FRL Unit (GC30008LNT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/4" ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadNPT
$100.01 $107.51Save 6% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC300-08 drain, gauge and thread option on one page All GC300-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC300-08 FRL Unit (GC30008LNT)

GC30008LNT is an AirTAC G-series three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator supplied as one set. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. the L code selects the low-pressure regulator type, and the N code means the set is supplied without a pressure gauge. It cleans the compressed air, holds downstream pressure steady and meters oil mist into the line in one assembly, with polycarbonate filter and lubricator bowls at this size and a -5 to 70 C working range on compressed air only.

This is a genuine AirTAC part. The G series is offered in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, and options including manual or automatic drains, a 5 um element (W), gauges with MPa, psi or bar scales, and G(BSPP) or NPT threads. Flow is published as curves rather than a single rated figure, so we confirm datasheet and sizing details on request.

AirTAC GC300-08 FRL Unit (GC30008LNT) Technical Specifications

ModelAirTAC GC300-08 FRL Unit (GC30008LNT)
SeriesGC300 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC300-08 FRL Unit (GC30008LNT)

GC300G-series F.R.L. combination, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF300-08 filter, GR300-08 regulator and GL300-08 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC300 · PT1/4" · 40 µm
One size downGC200
One size upGC400
Two-unit equivalentGFC300-08
Build orderFilter → regulator → lubricator

Where the AirTAC GC300-08 FRL Unit (GC30008LNT) Is Used

factory

General plant air drops

A no-frills conditioner for plant air drops feeding general pneumatic equipment, delivering filtered, regulated and lubricated air where pressure is read elsewhere on the line.

conveyor_belt

Sorter and diverter actuators

Supplying conditioned air to the diverter and pusher cylinders on a warehouse conveyor, with the regulator set once at the unit during commissioning.

build

Jig and clamp supply

Feeding workholding clamps and swing cylinders on welding or assembly jigs, where the regulator holds a fixed clamp pressure and the lubricator protects the seals.

Is the AirTAC GC300-08 FRL Unit (GC30008LNT) the Right Station?

Size 300 with 1/4 inch NPT ports is the mid step of the G series; drop to 200 or step to 400/600 as circuit demand changes. Drain is differential-pressure as built; manual (M) and automatic (A) are order options, as is the 5 um W element instead of the 40 um standard. This version has no gauge; This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Flow appears only as catalogue curves, so ask us to confirm sizing against your application before ordering.

AirtacDistr lists every GC300-08 order code with its price on one page at https://airtacdistr.com/products/airtac-gc300-08-three-unit-frl

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR300-08 regulator with a GF300-08 filter on that branch.

AirTAC GC300-08 FRL Unit (GC30008LNT) FAQ

AirTAC publishes G-series flow as performance curves rather than a single rated number, so we do not quote a flow figure here. Share your operating pressure and demand and we will confirm the datasheet curves and check that size 300 with 1/4 inch ports fits before you order.

The N code in the model means the set is supplied without a gauge, for installations that read pressure elsewhere on the line. Versions with an embedded square gauge or an external round gauge in MPa, psi or bar scales carry different order codes in the same size 300, 1/4 inch package - ask us for details.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC300-08 FRL Unit (GC30008LNT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.