The AirTAC GC400-15 FRL Unit (GC40015ALF1WT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC40015ALF1WT is the 400-size, three-unit F.R.L. combination from AirTAC's G series: a separate air filter, pressure regulator and lubricator working together as one set to clean, regulate and oil-mist-lubricate compressed air. This configuration is built for 1/2 in. NPT ports, carries an automatic drain on the filter bowl, uses the finer 5 um filtration element (the W grade), is the low-pressure regulator type, and includes an embedded square gauge scaled in MPa. Maximum working pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The G series F.R.L. family spans sizes 200, 300, 400 and 600, with a choice of drain type, filtration grade, gauge and thread; This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Published flow data appears as curves rather than a single rating, so we confirm flow and datasheet figures for your application on request.
| Model | AirTAC GC400-15 FRL Unit (GC40015ALF1WT) |
|---|---|
| Series | GC400 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC400 | G-series F.R.L. combination, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC400 · PT1/2" · 5 µm |
|---|---|
| One size down | GC300 |
| One size up | GC600 |
| Two-unit equivalent | GFC400-15 |
| Build order | Filter → regulator → lubricator |
Prepares air for the tool-change cylinders and clamping fixtures on a machining centre, where the 5 um element protects precision valves from fine particulate carryover.
Conditions the air feeding grip, divert and stopper cylinders along a bottling conveyor, with the automatic drain clearing condensate during continuous shifts.
Supplies filtered, regulated and lubricated air to bench-top test rigs and automated lab equipment, where the 5 um grade and low-pressure regulator suit sensitive downstream components.
Size 400 with 1/2 in. NPT ports is the mid-range step in the G series; move to 200 or 300 for smaller circuits or 600 for the largest ports and flow demand. The drain here is automatic, keeping condensate off the bowl without operator attention; manual and differential-pressure drains are the other coded choices. The W in the code selects the 5 um filter element instead of the 40 um standard, the right call where finer air quality matters. The gauge is the embedded square type with an MPa scale; psi and bar scales, an external round gauge, or no gauge are alternative codes, and three thread types (NPT on this code) can be ordered.
Flow for this family is published as curves, not as a single rated figure, so ask us to confirm sizing against your application before ordering.
AirtacDistr lists every GC400-15 order code with its price on one page at https://airtacdistr.com/products/airtac-gc400-15-three-unit-frl
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.
AirTAC publishes G series flow as curves, not as a single rated number, so we do not quote a figure here. Send us your operating pressure and air demand and we will confirm the flow from the datasheet on request before you order.
W selects the 5 um filtration element instead of the 40 um standard grade, giving finer removal of water droplets and particulate in the filter stage. Everything else in the code - 400 size, 1/2 in. NPT ports, automatic drain, low-pressure regulator and square MPa gauge - stays as decoded.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.