AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-15 FRL Unit (GC40015ALF1WT)

The AirTAC GC400-15 FRL Unit (GC40015ALF1WT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$168.92 $176.42Save 4% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC400-15 FRL Unit (GC40015ALF1WT)

GC40015ALF1WT is the 400-size, three-unit F.R.L. combination from AirTAC's G series: a separate air filter, pressure regulator and lubricator working together as one set to clean, regulate and oil-mist-lubricate compressed air. This configuration is built for 1/2 in. NPT ports, carries an automatic drain on the filter bowl, uses the finer 5 um filtration element (the W grade), is the low-pressure regulator type, and includes an embedded square gauge scaled in MPa. Maximum working pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The G series F.R.L. family spans sizes 200, 300, 400 and 600, with a choice of drain type, filtration grade, gauge and thread; This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Published flow data appears as curves rather than a single rating, so we confirm flow and datasheet figures for your application on request.

AirTAC GC400-15 FRL Unit (GC40015ALF1WT) Technical Specifications

ModelAirTAC GC400-15 FRL Unit (GC40015ALF1WT)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — square, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-15 FRL Unit (GC40015ALF1WT)

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-15 FRL Unit (GC40015ALF1WT) Is Used

precision_manufacturing

CNC machine tool pneumatics

Prepares air for the tool-change cylinders and clamping fixtures on a machining centre, where the 5 um element protects precision valves from fine particulate carryover.

conveyor_belt

Bottling and filling line actuators

Conditions the air feeding grip, divert and stopper cylinders along a bottling conveyor, with the automatic drain clearing condensate during continuous shifts.

science

Laboratory automation and test rigs

Supplies filtered, regulated and lubricated air to bench-top test rigs and automated lab equipment, where the 5 um grade and low-pressure regulator suit sensitive downstream components.

Is the AirTAC GC400-15 FRL Unit (GC40015ALF1WT) the Right Station?

Size 400 with 1/2 in. NPT ports is the mid-range step in the G series; move to 200 or 300 for smaller circuits or 600 for the largest ports and flow demand. The drain here is automatic, keeping condensate off the bowl without operator attention; manual and differential-pressure drains are the other coded choices. The W in the code selects the 5 um filter element instead of the 40 um standard, the right call where finer air quality matters. The gauge is the embedded square type with an MPa scale; psi and bar scales, an external round gauge, or no gauge are alternative codes, and three thread types (NPT on this code) can be ordered.

Flow for this family is published as curves, not as a single rated figure, so ask us to confirm sizing against your application before ordering.

AirtacDistr lists every GC400-15 order code with its price on one page at https://airtacdistr.com/products/airtac-gc400-15-three-unit-frl

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

AirTAC GC400-15 FRL Unit (GC40015ALF1WT) FAQ

AirTAC publishes G series flow as curves, not as a single rated number, so we do not quote a figure here. Send us your operating pressure and air demand and we will confirm the flow from the datasheet on request before you order.

W selects the 5 um filtration element instead of the 40 um standard grade, giving finer removal of water droplets and particulate in the filter stage. Everything else in the code - 400 size, 1/2 in. NPT ports, automatic drain, low-pressure regulator and square MPa gauge - stays as decoded.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC400-15 FRL Unit (GC40015ALF1WT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.