verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

AirTAC GC400-15 FRL Unit (GC40015LC1WT)

The AirTAC GC400-15 FRL Unit (GC40015LC1WT) is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT1/2" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$155.22 $162.72Save 4% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GC400-15 drain, gauge and thread option on one page All GC400-15 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GC400-15 FRL Unit (GC40015LC1WT)

The AirTAC GC40015LC1WT is a three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator assembled as one set. The W suffix specifies the finer 5 um filter element, the low-pressure (L) type regulator sets downstream pressure, the lubricator meters oil mist to downstream equipment, and the differential-pressure drain handles condensate. The 400 size carries a NPT1/2 port and the MPa round gauge is included.

This is a genuine AirTAC part, available across the 200/300/400/600 sizes with ports from 1/8" to 1", G(BSPP) and NPT thread options, automatic or manual drain variants and the standard 40 um element. Flow is published as curves, not a single rating, so we confirm the datasheet figures for your application on request.

AirTAC GC400-15 FRL Unit (GC40015LC1WT) Technical Specifications

ModelAirTAC GC400-15 FRL Unit (GC40015LC1WT)
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT1/2" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GC400-15 FRL Unit (GC40015LC1WT)

GC400G-series F.R.L. combination, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-15 filter, GR400-15 regulator and GL400-15 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT1/2" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-15
Build orderFilter → regulator → lubricator

Where the AirTAC GC400-15 FRL Unit (GC40015LC1WT) Is Used

view_module

Carton-sorter pilot valve manifolds

Feeds the pilot-air manifold of a carton sorting line, where the 5 um element keeps fine particles out of the densely packed directional valves that divert boxes between lanes.

science

Pneumatic valve test benches

Supplies clean, regulated and lubricated air to a workshop bench cycling test valves, so results are not spoiled by water or debris in the supply while the regulator holds the test pressure.

engineering

Weld-cell clamping fixtures

Prepares the air for weld-cell clamp and positioner cylinders on a fabrication line, protecting solenoid valves from weld-shop particulate and keeping clamping action consistently lubricated.

Is the AirTAC GC400-15 FRL Unit (GC40015LC1WT) the Right Station?

Choose the 400 size with its 1/2" NPT port when your circuit's air demand and porting call for it; smaller 200/300 or larger 600 sizes step the port from 1/8" to 1". The W code gives 5 um filtration - select it where finer particle removal protects pilot valves; otherwise the 40 um standard element is the default. Drain is differential-pressure here; automatic (A) and manual (M) are options. The MPa round gauge is fitted, with square-gauge and psi/bar scale variants orderable, and G(BSPP)/NPT threads and bracket arrangements are catalogue choices.

Because flow for this series is published only as curves, ask us to confirm sizing against your application before you order.

AirtacDistr lists every GC400-15 order code with its price on one page at https://airtacdistr.com/products/airtac-gc400-15-three-unit-frl

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-15 regulator with a GF400-15 filter on that branch.

AirTAC GC400-15 FRL Unit (GC40015LC1WT) FAQ

AirTAC publishes GC-series flow as characteristic curves rather than a single rated number, so we do not quote a rated l/min or SCFM figure. Share your duty cycle and downstream demand and we will confirm the flow and datasheet figures for this 400-size, 1/2"-port set on request.

The blank filter position decodes to a 40 um element, the series standard for general plant air. The W suffix in this model specifies the optional 5 um element - the right choice when downstream pilot-operated valves, precision cylinders or test equipment need finer particle removal from the same filtered, regulated and lubricated supply.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GC400-15 FRL Unit (GC40015LC1WT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.