AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

AirTAC GFC300-10 Combination Unit (GFC30010ALC1WT)

The AirTAC GFC300-10 Combination Unit (GFC30010ALC1WT) is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 5 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$94.26 $101.76Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GFC300-10 drain, gauge and thread option on one page All GFC300-10 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC GFC300-10 Combination Unit (GFC30010ALC1WT)

The AirTAC GFC30010ALC1WT is a two-unit air preparation set: a filter-regulator plus a lubricator. The L marks the low-pressure regulator type for circuits running well below standard shop pressure, with an adjusting range up to 0.4 MPa. The W at the end of the code specifies the finer 5 um filter element, so the air reaching your actuators is both moisture-controlled and more finely filtered than the 40 um standard. The automatic drain clears condensate without manual attention, the lubricator meters oil mist downstream, and the 300 size carries NPT3/8 ports with a round external gauge scaled in MPa.

This is a genuine AirTAC part. The G series spans 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, and this set can alternatively be ordered with the 40 um standard element, a manual or differential-pressure drain, a square embedded gauge with MPa, psi or bar scale, the standard-pressure regulator type, and G (BSPP) or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm sizing and the datasheet for your application.

AirTAC GFC300-10 Combination Unit (GFC30010ALC1WT) Technical Specifications

ModelAirTAC GFC300-10 Combination Unit (GFC30010ALC1WT)
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GFC300-10 Combination Unit (GFC30010ALC1WT)

GFC300G-series two-unit set, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-10 filter regulator and GL300-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT3/8" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-10
Build orderFilter regulator first, lubricator last

Where the AirTAC GFC300-10 Combination Unit (GFC30010ALC1WT) Is Used

view_module

Electronics assembly pick-and-place benches

Gentle low-pressure grippers on an SMT bench stay reliable when the supply is finely filtered as well as regulated. This set combines the low-pressure regulator and 5 um element so dust and moisture never reach the small cylinders and valves.

conveyor_belt

Bottling line low-pressure capper actuators

Reduced-pressure capper and sorter cylinders on a bottling line get air that is filtered to 5 um, held at the dialed-down pressure and lightly oiled, with the automatic drain coping with condensate in a washdown-prone area.

science

Laboratory sample-handling actuators

Lab automation that moves sample trays at modest pressures benefits from cleaner air: the 5 um element keeps fine particulate out of precision actuators while the low-pressure regulator protects delicate loads.

Is the AirTAC GFC300-10 Combination Unit (GFC30010ALC1WT) the Right Set?

Take the 300/NPT3/8 size for 3/8 inch plumbing in the mid flow range; 200 fits compact circuits, 400 and 600 serve larger ports. Choose this L type when the circuit runs at reduced pressure, with adjusting range up to 0.4 MPa, or the standard type for conventional line pressure. The 5 um W element suits valves and cylinders sensitive to fine particulate; the 40 um grade is the standard alternative. The automatic drain fits unattended installations, with manual and differential-pressure drains also available. The round external MPa gauge can be replaced by a square embedded gauge in MPa, psi or bar. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Since flow is published as curves, not a single rating, ask us to confirm sizing against your application before ordering.

AirtacDistr lists every GFC300-10 order code with its price on one page at https://airtacdistr.com/products/airtac-gfc300-10-two-unit-frl

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-10 filter regulator on its own.

AirTAC GFC300-10 Combination Unit (GFC30010ALC1WT) FAQ

AirTAC publishes G-series flow as curves rather than a single rated figure, so we cannot quote one number. Give us your operating pressure and expected demand and we will confirm sizing against the datasheet curves on request.

Choose the W element when downstream valves, cylinders or instruments are sensitive to fine particulate, for example precision grippers or instrumentation take-offs. The 40 um standard grade is the right choice for general shop-air service where finer filtration is not required.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC GFC300-10 Combination Unit (GFC30010ALC1WT)

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.