The AirTAC Airtac GAC F.R.L. Unit GAC20008ALNK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for compact pneumatics, this AirTAC combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/4in ported body operates at 0.15-0.4 MPa (20-58 psi) and uses a 40 um element. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling of the internal pressure-control mechanisms.
Weighing 750 g, this unit pairs a 25 cc condensate bowl with a 36 cc oil reservoir. The automatic drain clears liquid without an operator, and the reverse-flow (reflux) valve is fitted, which the catalogue shows as a separate pneumatic symbol. No gauge is supplied, but a 1/8in connection is available if you need to add instrumentation to read the set pressure.
| Model | Airtac GAC F.R.L. Unit GAC20008ALNK |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC200 is 1/8" if you add one.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF200-08 filter, GAR200-08 regulator, GAL200-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure air to delicate testing jigs where a 1/4in port and a 0.4 MPa ceiling protect sensitive actuators from overpressure.
Conditions air for benchtop analytical instruments, relying on the automatic drain to clear condensate during continuous unattended cycles.
Supplies a controlled oil mist to low-torque air screwdrivers, keeping internal vanes lubricated without exceeding 0.4 MPa.
Choose this lower-pressure type for equipment strictly capped at 0.4 MPa, and step up to a GAC300 if your line needs the 3000 L/min plotted flow envelope instead of this body's 1750 L/min at 0.7 MPa inlet. The PC bowl, 40 um element and PT thread with an MPa/psi gauge scale suit standard factory air, while the automatic drain favours unattended machinery. If the downstream line must remain oil-free, select a filter-regulator instead of this lubricated assembly, and remember that GAF200-08, GAR200-08 and GAL200-08 are the exact replacement units. Choosing the L type limits you to 44% of the standard 0.9 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) against a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, uses a 40 um element, and weighs 750 g. The drain bowl holds 25 cc, the oil bowl holds 36 cc, and ISO VG 32 is the recommended lubricant.
The N in the ordering code means no gauge is supplied. The body features a 1/8in gauge connection, allowing you to install a separate PT-threaded gauge reading in MPa/psi to monitor the 0.15-0.4 MPa range. The K code indicates a reverse-flow valve is also fitted.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.