verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAC200 · F.R.L. Combination (Filter + Regulator + Lubricator)

Airtac GAC F.R.L. Unit GAC20008ALNWK

The AirTAC Airtac GAC F.R.L. Unit GAC20008ALNWK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/4"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade5 µm
  • Bowl materialPC
  • Drainautomatic
  • Pressure gaugeNot fitted
  • Weight750 g
$81.99 $91.21Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAC F.R.L. Unit GAC20008ALNWK

Delivering cleaned, regulated and lubricated air for pneumatic setups, this GAC200 unit integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/4in port serves lighter duties, while the 5 um element captures fine particulates before they reach sensitive valves. Because the lubricator sits downstream of the regulator, oil mist is introduced after pressure control, keeping the regulating seat clean.

This specific configuration carries an automatic drain to expel condensate from the 25 cc bowl without operator intervention. No gauge is supplied, but a 1/8in connection allows adding one if visual pressure monitoring becomes necessary. The reverse-flow (reflux) valve is fitted, appearing as a separate pneumatic symbol in the catalogue.

Airtac GAC F.R.L. Unit GAC20008ALNWK Technical Specifications

ModelAirtac GAC F.R.L. Unit GAC20008ALNWK
SeriesGAC200 F.R.L. combination
Port size1/4" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialPC
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl25 cc
Capacity of oil bowl36 cc
Recommended lubricantISO VG 32 or equivalent
Weight750 g

Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC200 is 1/8" if you add one.

Model Code: Airtac GAC F.R.L. Unit GAC20008ALNWK

GAC200GA200 series F.R.L. unit — sets ports, bowl capacity and weight.
(blank)Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N).
08Port size 1/4". This body offers 06 = 1/8", 08 = 1/4".
ADrain: Automatic drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/8" gauge connection.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAF200-08 filter, GAR200-08 regulator, GAL200-08 lubricator — all three share this body and port.

Size Class & Flow Envelope

  • GAC2001/8"-1/4" · 1750 L/min
  • GAC3001/4"-1/2" · 3000 L/min
  • GAC4003/8"-1/2" · 6000 L/min
  • GAC5003/4" · 7000 L/min
  • GAC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAC200 · 1/4" · curve to 1750 L/min
One size upGAC300 (curve to 3000 L/min)
Build orderFilter → bracket → regulator → lubricator

Where the Airtac GAC F.R.L. Unit GAC20008ALNWK Is Used

precision_manufacturing

Micro-Assembly Jigs

Feeds small-bore cylinders handling delicate electronics where a 5 um element prevents grit from jamming precision moving parts.

science

Lab Pneumatic Stations

Conditions air for benchtop test rigs operating under 0.4 MPa, using the automatic drain to handle condensate during long unattended test cycles.

straighten

Textile Guiding Air

Supplies low-pressure air to yarn guides and tensioning cylinders, adding a controlled oil mist to protect high-speed friction surfaces.

Is the Airtac GAC F.R.L. Unit GAC20008ALNWK the Right Air-Prep Unit?

Choose this assembly for low-pressure circuits requiring fine filtration and unattended condensate management. The lower-pressure type restricts output to 0.15-0.4 MPa (20-58 psi); if your machine might ever exceed 0.4 MPa, select a standard type instead. The PC bowl suits general industrial environments, while the 5 um element demands more frequent service than the standard 40 um grade to maintain flow. If the downstream line must remain oil-free, omit the lubricator and choose a filter-regulator configuration. Replacement spares follow the body and port directly: GAF200-08, GAR200-08 and GAL200-08. Stepping up to the GAC300 increases the plotted flow envelope from 1750 to 3000 L/min at 0.7 MPa inlet, a 1.7x jump in sizing capacity.

Quick checklist

  • ✓ Body size for your peak flow (1/4" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 25 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 750 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.

Airtac GAC F.R.L. Unit GAC20008ALNWK FAQ

This lower-pressure F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It features a 25 cc drain bowl, a 36 cc oil bowl, a 5 um element, and weighs 750 g. The unit functions from -5 to 70 C and uses ISO VG 32 lubricant.

The letters indicate an automatic drain (A), lower-pressure type (L), no gauge (N), 5 um element (W) and a reverse-flow valve (K). Since no gauge is included, you must add one to the 1/8in port to read the set pressure. The reflux valve is shown as a distinct symbol in the catalogue.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAC F.R.L. Unit GAC20008ALNWK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAC20008ALNWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.