verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GAC200 · F.R.L. Combination (Filter + Regulator + Lubricator)

Airtac GAC F.R.L. Unit GAC20008ALTK

The AirTAC GAC F.R.L. Unit GAC20008ALTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/4"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialPC
  • Drainautomatic
  • Pressure gaugeCircular, psi / bar
  • Weight750 g
$87.46 $94.96Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GAC200-08 bowl, type and element option on one page All GAC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the Airtac GAC F.R.L. Unit GAC20008ALTK

Supplying a precise 1/4in port, this AirTAC unit conditions line air through a filter, regulator and lubricator pre-plumbed on a single L-shape bracket. The lower-pressure type restricts the operating band to 0.15-0.4 MPa (20-58 psi), while a 40 um element extracts particulate before the lubricator introduces a controlled oil mist downstream of the regulation stage.

Weighing 750 g, the assembly integrates an automatic drain on its 25 cc condensate bowl to clear water without operator input. A circular gauge reading MPa/psi is fitted for the default NPT thread, and the catalogue lists the reverse-flow (reflux) valve as a separate pneumatic symbol on its own page. Order code GAC20008ALTK has NPT ports (the T in the code) for North American pipe fittings.

Airtac GAC F.R.L. Unit GAC20008ALTK Technical Specifications

ModelAirtac GAC F.R.L. Unit GAC20008ALTK
SeriesGAC200 F.R.L. combination
Port size1/4" (NPT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialPC
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl25 cc
Capacity of oil bowl36 cc
Recommended lubricantISO VG 32 or equivalent
Weight750 g

Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.

Model Code: Airtac GAC F.R.L. Unit GAC20008ALTK

GAC200GA200 series F.R.L. unit — sets ports, bowl capacity and weight.
(blank)Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N).
08Port size 1/4". This body offers 06 = 1/8", 08 = 1/4".
ADrain: Automatic drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
(blank)Filtering grade 40 µm.
TNPT thread; gauge scale psi / bar.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAF200-08 filter, GAR200-08 regulator, GAL200-08 lubricator — all three share this body and port.

Size Class & Flow Envelope

  • GAC2001/8"-1/4" · 1750 L/min
  • GAC3001/4"-1/2" · 3000 L/min
  • GAC4003/8"-1/2" · 6000 L/min
  • GAC5003/4" · 7000 L/min
  • GAC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAC200 · 1/4" · curve to 1750 L/min
One size upGAC300 (curve to 3000 L/min)
Build orderFilter → bracket → regulator → lubricator

Where the Airtac GAC F.R.L. Unit GAC20008ALTK Is Used

handyman

Small Pneumatic Clamps

Feeds low-pressure actuation for delicate benchtop clamping jigs where a 1/4in port and 40 um filtration protect sensitive seals.

science

Lab Air Tools

Conditions supply for laboratory-scale air agitators or low-force pick-and-place probes requiring a steady 0.15-0.4 MPa output.

precision_manufacturing

Textile Guiders

Regulates yarn-guiding cylinders that demand gentle pressure and oil-mist lubrication to prevent sticking in continuous motion.

Is the Airtac GAC F.R.L. Unit GAC20008ALTK the Right Air-Prep Unit?

Choose this compact body for single actuators or small jigs, stepping up to the GAC300 if you need a 60 cc drain bowl or a flow envelope plotted to 3000 L/min at 0.7 MPa inlet. The automatic drain suits unattended wet lines, and the fitted gauge lets operators verify the low-pressure setpoint directly. If the downstream line must stay oil-free, select a filter-regulator instead of this lubricated assembly. Spares follow the body-port suffix exactly: GAF200-08, GAR200-08 and GAL200-08. Because the L type tops out at 0.4 MPa, it provides only 44% of the Standard type's 0.9 MPa ceiling.

AirtacDistr lists every GAC200-08 order code with its price on one page at https://airtacdistr.com/products/airtac-gac200-08-three-unit-frl

Quick checklist

  • ✓ Body size for your peak flow (1/4" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 25 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 750 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.

Airtac GAC F.R.L. Unit GAC20008ALTK FAQ

This lower-pressure F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It features a 1/4in port, a 25 cc drain bowl, a 36 cc oil bowl, a 40 um element, and a temperature range of -5 to 70 C. The unit weighs 750 g and uses ISO VG 32 lubricant.

The K indicates that a reverse-flow (reflux) valve is fitted to this assembly. The official catalogue shows this valve as a separate pneumatic symbol with full details provided on its own dedicated page.

T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for Airtac GAC F.R.L. Unit GAC20008ALTK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.