The AirTAC Airtac GAC F.R.L. Unit GAC20008ALWK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for pneumatics, this GAC200 unit integrates a filter, regulator and lubricator on a single L-shape bracket. The 1/4in port pairs with a 5 um element to trap fine particles before they reach precision valves. Because the lubricator sits last in the sequence, oil mist is added downstream of the regulator seat, preventing fouling. A circular gauge is fitted, reading MPa/psi for the default PT thread, while the automatic drain clears condensate without an operator.
The lower-pressure type restricts the operating range to 0.15-0.4 MPa (20-58 psi). This assembly includes a reverse-flow (reflux) valve, which the catalogue shows as a separate pneumatic symbol with details on its own page. Weighing 750 g, the unit carries a 25 cc condensate bowl and a 36 cc oil reservoir. If the downstream line must stay oil-free, omit the lubricator and choose a filter-regulator instead.
| Model | Airtac GAC F.R.L. Unit GAC20008ALWK |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF200-08 filter, GAR200-08 regulator, GAL200-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds clean, finely filtered 5 um air to sensitive solenoid valves in small pneumatic logic panels where particulates would cause sticking.
Supplies regulated, lubricated air at low pressure to light-duty benchtop grinders or small drills, extending spindle life via downstream oil mist.
Conditions air for compact laboratory actuators requiring a strict 0.15-0.4 MPa operating window and automatic condensate removal during unattended tests.
Choose this assembly for light-duty circuits needing fine filtration and low pressure. The 5 um element catches far finer particulates than the standard 40 um grade, suiting instrument air or sensitive valves, though it requires more frequent element service. The automatic drain is decisive for unattended or wet lines, emptying the 25 cc bowl without manual intervention. For maintenance, the individual units are separately orderable as GAF200-08, GAR200-08 and GAL200-08, so a clogged element never means replacing the whole bracket. The catalogue flow curve for the GAC200 is plotted to 1750 L/min at 0.7 MPa inlet, which is roughly 58% of the GAC300's 3000 L/min envelope, making it better for single actuators than multi-station headers. Finally, the 0.4 MPa ceiling is 44% of the Standard type's 0.9 MPa maximum, so confirm your machine will never need higher pressure before specifying this L type.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This model operates at 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It features a 25 cc drain bowl, a 36 cc oil bowl, a 5 um element, and weighs 750 g. The recommended lubricant is ISO VG 32 or equivalent.
This unit includes a reverse-flow (reflux) valve, which the catalogue draws as a separate pneumatic symbol. Details regarding its specific function are deferred to its own page in the catalogue, so confirm from the datasheet for application integration.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.