The AirTAC Airtac GAC F.R.L. Unit GAC20008LW is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for pneumatic setups, this assembly integrates a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. It features a 1/4in port, a 5 um element for trapping fine particles, and a lower pressure range of 0.15-0.4 MPa (20-58 psi). The build routes air through the filter first, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls.
A circular gauge is fitted to read the set pressure in MPa/psi, matching the default PT thread. Weighing 750 g with a 25 cc condensate bowl and a 36 cc oil reservoir, this compact body suits light-duty tasks. The unit carries a 1.0 MPa (145 psi) maximum pressure and a 1.5 MPa (215 psi) proof rating, operating between -5 to 70 C using ISO VG 32 lubricant. If your downstream line must remain strictly oil-free, omit the lubricator and choose a filter-regulator instead.
| Model | Airtac GAC F.R.L. Unit GAC20008LW |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF200-08 filter, GAR200-08 regulator, GAL200-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds clean, finely filtered 5 um air to sensitive directional control valves in small pneumatic logic circuits where standard 40 um filtration is too coarse.
Conditions supply for single-actuator benchtop assemblies or light-duty power tools, adding a controlled oil mist to protect internal moving parts from wear.
Regulates low-pressure air down to the 0.15-0.4 MPa range for delicate clamping jigs and test fixtures that require stable, non-aggressive actuation forces.
This model uses a PC bowl and ships with both a semi-auto and a manual drain fitted; the semi-auto dumps condensate on every pressure drop, while the manual option allows on-demand emptying. The 5 um element catches far finer particulate than the standard 40 um grade, making it ideal for precision valves, though it will require more frequent element service. For spares, the three components are separately orderable as GAF200-08, GAR200-08 and GAL200-08, meaning a clogged filter or damaged bowl does not require replacing the whole assembly. Stepping up to the GAC300 body raises the plotted flow envelope to 3000 L/min at 0.7 MPa inlet compared to this unit's 1750 L/min, roughly doubling the available capacity for larger duties. Because the lower pressure type tops out at 0.4 MPa, it operates at just 44% of the standard 0.9 MPa ceiling, so choose this only if the machine will never need higher pressure.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates in temperatures from -5 to 70 C, weighs 750 g, and uses a 25 cc drain bowl alongside a 36 cc oil bowl. The recommended lubricant is ISO VG 32 or equivalent.
The L indicates the lower 0.15-0.4 MPa pressure range, making it unsuitable for systems that might ever require more than 0.4 MPa. The W denotes a 5 um filtering element, which traps finer particles than the standard 40 um grade for precision equipment but needs more frequent replacement.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.