verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAC200 · F.R.L. Combination (Filter + Regulator + Lubricator)

Airtac GAC F.R.L. Unit GAC200C08ALNK

The AirTAC Airtac GAC F.R.L. Unit GAC200C08ALNK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/4"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade40 µm
  • Bowl materialMetal
  • Drainautomatic
  • Pressure gaugeNot fitted
  • Weight750 g
$88.53 $98.19Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAC F.R.L. Unit GAC200C08ALNK

Configured with a 1/4in port, this AirTAC unit delivers cleaned, regulated and oil-misted air by combining a filter, regulator and lubricator on a single L-shape bracket. The metal bowl equips this 750 g assembly, and the automatic drain actively clears the 25 cc condensate sump without operator input. As a lower-pressure type, it regulates between 0.15-0.4 MPa (20-58 psi) and uses a 40 um element.

Because no gauge is supplied, the set pressure cannot be read without adding one to the 1/8in gauge connection. The reverse-flow (reflux) valve is fitted, which the catalogue shows as a separate pneumatic symbol with details on its own page. Air passes the filter, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls.

Airtac GAC F.R.L. Unit GAC200C08ALNK Technical Specifications

ModelAirtac GAC F.R.L. Unit GAC200C08ALNK
SeriesGAC200 F.R.L. combination
Port size1/4" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialMetal
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl25 cc
Capacity of oil bowl36 cc
Recommended lubricantISO VG 32 or equivalent
Weight750 g

Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC200 is 1/8" if you add one.

Model Code: Airtac GAC F.R.L. Unit GAC200C08ALNK

GAC200GA200 series F.R.L. unit — sets ports, bowl capacity and weight.
CBowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N).
08Port size 1/4". This body offers 06 = 1/8", 08 = 1/4".
ADrain: Automatic drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/8" gauge connection.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAF200-08 filter, GAR200-08 regulator, GAL200-08 lubricator — all three share this body and port.

Size Class & Flow Envelope

  • GAC2001/8"-1/4" · 1750 L/min
  • GAC3001/4"-1/2" · 3000 L/min
  • GAC4003/8"-1/2" · 6000 L/min
  • GAC5003/4" · 7000 L/min
  • GAC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAC200 · 1/4" · curve to 1750 L/min
One size upGAC300 (curve to 3000 L/min)
Build orderFilter → bracket → regulator → lubricator

Where the Airtac GAC F.R.L. Unit GAC200C08ALNK Is Used

precision_manufacturing

Low-Force Pneumatic Clamps

Feeds small clamping cylinders on an electronics assembly jig where delicate handling requires a strictly limited 0.4 MPa output.

science

Lab Automation Actuators

Conditions air for single-actuator test fixtures, adding necessary oil mist while the automatic drain handles condensate removal autonomously.

handyman

Air-Powered Hand Tools

Supplies metered, lubricated air to benchtop grinders in a workshop, protecting internal vanes from wear via downstream oil injection.

Is the Airtac GAC F.R.L. Unit GAC200C08ALNK the Right Air-Prep Unit?

This assembly uses a metal bowl and an automatic drain, making it suitable for wet lines where unattended condensate removal is preferred over the standard semi-auto and manual pair. The lower-pressure type tops out at 0.4 MPa, so if the machine may ever need more, this is the wrong part. The 40 um element is standard, and the PT thread sets the gauge scale to MPa/psi if a gauge is added later. The three units are separately orderable as GAF200-08, GAR200-08 and GAL200-08, so a damaged bowl does not mean replacing the whole assembly. The 0.4 MPa ceiling is 44% of the Standard type's 0.9 MPa maximum, quantifying exactly what the buyer gives up when choosing this L type.

Quick checklist

  • ✓ Body size for your peak flow (1/4" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 25 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 750 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.

Airtac GAC F.R.L. Unit GAC200C08ALNK FAQ

This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 750 g, has a 25 cc drain bowl, a 36 cc oil bowl, and uses ISO VG 32 lubricant.

The N in the model code means no gauge is supplied from the factory. You can add a circular gauge to the 1/8in connection on the body, which will read in MPa/psi for the default PT thread, allowing operators to monitor the downstream setpoint.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAC F.R.L. Unit GAC200C08ALNK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAC200C08ALNK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.