The AirTAC Airtac GAC F.R.L. Unit GAC200C08ALWK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for compact pneumatics, this GAC200 unit combines a filter, regulator and lubricator on a single L-shape bracket. It features a 1/4in port, a metal bowl and a 5 um element. The lower-pressure type restricts the operating range to 0.15-0.4 MPa (20-58 psi). Because the lubricator sits last in the sequence, oil mist enters the airstream downstream of the regulator seat, preventing fouling.
Weighing 750 g, this assembly is sized for small jigs rather than main plant headers. The automatic drain empties the 25 cc condensate bowl without an operator, which suits unattended or wet lines. A circular gauge is fitted, reading MPa/psi for the default PT thread. The reverse-flow (reflux) valve is fitted, shown in the catalogue as a separate pneumatic symbol with details on its own page.
| Model | Airtac GAC F.R.L. Unit GAC200C08ALWK |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF200-08 filter, GAR200-08 regulator, GAL200-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds sensitive pneumatic logic and low-pressure pilot valves requiring finely filtered 5 um air to prevent sticking.
Conditions air for single-actuator bench jigs where a 1/4in port and a 750 g footprint fit tight tooling spaces.
Supplies regulated, lubricated air to low-force lab devices operating safely under the 0.4 MPa ceiling.
Choose this assembly when a low-pressure circuit requires fine filtration and unattended drainage. The 5 um element traps far finer particles than the standard 40 um grade, protecting precision valves at the cost of more frequent element service. If the machine may ever need more than 0.4 MPa, the L type is the wrong part. The metal bowl suits harsher environments, though buyers should confirm compatibility for aggressive surroundings. Because oil mist is added downstream, choose a filter-regulator instead if the line must stay oil-free. Spares are GAF200-08, GAR200-08 and GAL200-08. Stepping up to the GAC300 roughly doubles the flow envelope, as its curve is plotted to 3000 L/min at 0.7 MPa inlet versus 1750 L/min here. Note that 0.4 MPa is about 44% of the Standard type's 0.9 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi). Max pressure is 1.0 MPa (145 psi) and proof pressure is 1.5 MPa (215 psi). Temperature ranges from -5 to 70 C. The drain bowl holds 25 cc and the oil bowl holds 36 cc. Recommended lubricant is ISO VG 32. Total weight is 750 g.
The K indicates a reverse-flow (reflux) valve is fitted. The catalogue draws this as a separate pneumatic symbol, with specific functional details deferred to its own page.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.