The AirTAC GAC F.R.L. Unit GAC200C08ASN is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 1/4in port serves the compact 750 g GAC200 body, which pairs a 25 cc condensate bowl with a 36 cc oil reservoir.
This specific configuration uses a robust metal bowl and an automatic drain to clear moisture without an operator, making it well suited for unattended or wet lines. It regulates between 0.15-0.9 MPa (20-130 psi) using a standard 40 um element. Because the letter N follows the port, no pressure gauge is supplied from the factory; a 1/8in connection is provided if you choose to mount one later.
| Model | Airtac GAC F.R.L. Unit GAC200C08ASN |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC200 is 1/8" if you add one.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF200-08 filter, GAR200-08 regulator, GAL200-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds individual pneumatic hand tools or small jigs at a workstation where floor space is tight and a 1/4in connection is sufficient.
Conditions air for small solenoid valves and actuators on diagnostic or testing machinery, relying on the auto drain for unattended weekend runs.
Prepares supply for a standalone linear actuator or clamping cylinder, adding the required oil mist downstream of the regulator seat.
Choose this metal-bowl variant for environments where PC or nylon might not hold up, keeping in mind the 1.0 MPa maximum pressure and -5 to 70 C temperature limits apply equally to all bowl materials. The automatic drain is decisive for wet lines, whereas a blank drain code ships both semi-auto and manual options. Since no gauge is included here, the set pressure cannot be read without adding one to the 1/8in port. The 40 um element is standard, but a W code brings a 5 um element for precision instrument air. If the downstream line must stay oil-free, omit the lubricator and choose a filter-regulator instead. Spares follow the body-port suffix exactly: GAF200-08, GAR200-08 and GAL200-08. Because the 1.0 MPa maximum supply is only 0.1 MPa above the 0.9 MPa standard ceiling, plan a supply near 1.0 MPa if you truly need 0.9 MPa out.
AirtacDistr lists every GAC200-08 order code with its price on one page at https://airtacdistr.com/products/airtac-gac200-08-three-unit-frl
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 750 g, holds 25 cc of condensate and 36 cc of oil, and uses ISO VG 32 lubricant.
The N after the 08 port code indicates no gauge is supplied. You can install your own circular gauge using the 1/8in connection on the body, with the default PT thread reading in MPa/psi.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.