The AirTAC Airtac GAC F.R.L. Unit GAC200C08ASNWK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, pressure-set and oil-misted air, this AirTAC GAC200C08ASNWK is a complete three-unit F.R.L. combination pairing a filter, regulator and lubricator on a single L-shape bracket. The 1/4in port serves lighter duties, while the 5 um element traps far finer particles than the standard 40 um grade, suiting precision valves and instrument air. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling during pressure control.
This specific configuration uses a robust metal bowl paired with an automatic drain that clears condensate without an operator, a decisive feature for unattended or wet lines. No pressure gauge is supplied, but the body features a 1/8in gauge connection if you need to add one later to read the set pressure. The unit operates within the 0.15-0.9 MPa (20-130 psi) standard range, and the reverse-flow (reflux) valve is fitted, which the catalogue shows as a separate pneumatic symbol with details on its own page.
| Model | Airtac GAC F.R.L. Unit GAC200C08ASNWK |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC200 is 1/8" if you add one.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF200-08 filter, GAR200-08 regulator, GAL200-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds clean, finely filtered 5 um air to sensitive directional control valves in small pneumatic logic circuits.
Conditions air for single-actuator test fixtures, adding the required oil mist for smooth cylinder cycling.
Protects small automated assembly stations with its automatic drain, clearing condensate continuously without an operator.
Choose this 750 g assembly for single actuators or small jigs where space is tight, ensuring it mounts to a proper panel rather than relying on tubing support. If your machine requires oil-free air downstream, you must omit the lubricator and choose a separate filter-regulator instead. The metal bowl handles rugged environments, while the 5 um element demands more frequent service than the standard 40 um option to maintain protection for sensitive components. The three constituent units are separately orderable as GAF200-08, GAR200-08 and GAL200-08, so a clogged element or damaged bowl does not require replacing the whole assembly. The catalogue flow curve for the GAC200 is plotted to 1750 L/min at 0.7 MPa inlet, which is roughly 29% of the GAC300's 3000 L/min envelope, providing a clear sizing envelope for stepping up if demand increases. Because the maximum supply is 1.0 MPa and the standard type regulates to 0.9 MPa, there is only about 0.1 MPa of headroom above the top setting, so plan a supply near 1.0 MPa if you truly need 0.9 MPa out.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This model operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. It features a 25 cc drain bowl, a 36 cc oil bowl, and weighs 750 g.
The N in the ordering code indicates no gauge is supplied, meaning the set pressure cannot be read without adding one. The body includes a 1/8in gauge connection for easy field installation, and the default PT thread scale would read MPa/psi if a gauge is added.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.