The AirTAC GAC F.R.L. Unit GAC200C08LT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for light-duty pneumatics, this AirTAC combination pre-assembles a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 1/4in port serves the compact 750 g GAC200 body, while the metal bowl equips it for rugged surroundings. Because the 40 um filter sits upstream and oil mist is injected last, the regulator seat stays clean.
This variant uses the lower-pressure type, governing output strictly to 0.15-0.4 MPa (20-58 psi). A circular gauge is fitted to read the set point in MPa and psi, matching the default NPT thread. Condensate is managed by a paired semi-auto and manual drain system, relying on pressure drops or operator action to empty the 25 cc bowl. Order code GAC200C08LT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC200C08LT |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF200-08 filter, GAR200-08 regulator, GAL200-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure cylinders in light electronics assembly where delicate pick-and-place actuators require strictly governed 0.4 MPa air.
Conditions air for handheld pneumatic drivers on workbenches, adding necessary oil mist while the 25 cc drain bowl catches condensate.
Regulates supply for sensitive laboratory positioners, using the 40 um element to protect fine valves from particulate ingress.
Choose this 1/4in unit for low-force actuators where exceeding 0.4 MPa would damage downstream tooling. If your machine might eventually need standard 0.9 MPa pressure, the L type is the wrong choice. The metal bowl suits harsher industrial settings than the standard PC, though buyers should confirm chemical compatibility for aggressive fluids. The catalogue flow curve for the GAC200 is plotted to 1750 L/min at 0.7 MPa inlet, which is about 58% of the GAC300's 3000 L/min envelope, making it better for single jigs than multi-station headers. If the line must stay oil-free, omit the lubricator and choose a filter-regulator instead. For maintenance, order GAF200-08, GAR200-08 and GAL200-08. Note that 0.4 MPa is 44% of the standard 0.9 MPa ceiling.
AirtacDistr lists every GAC200-08 order code with its price on one page at https://airtacdistr.com/products/airtac-gac200-08-three-unit-frl
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates to 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 750 g, has a 25 cc drain bowl and a 36 cc oil bowl, and uses ISO VG 32 lubricant.
It ships with both a semi-auto drain that expels condensate on pressure drops and a manual drain for on-demand emptying. A circular gauge is fitted, reading in MPa and psi for the NPT thread, so operators can verify the low-pressure setting directly at the unit.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.