The AirTAC GAC F.R.L. Unit GAC200N08ALWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for compact pneumatics, this AirTAC unit integrates a filter, regulator and lubricator on a single L-shape bracket. It features a 1/4in port, a 5 um element for fine particle capture, and a nylon bowl. The lower-pressure type restricts the operating range to 0.15-0.4 MPa (20-58 psi).
Air passes through the filter first, then the regulator, before oil mist is introduced by the lubricator downstream of the regulator seat. The automatic drain clears condensate from the 25 cc bowl without operator intervention, while the fitted circular gauge reads MPa/psi for the default NPT thread. Weighing 750 g, this assembly suits light-duty installations where space is tight. Order code GAC200N08ALWT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC200N08ALWT |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/4" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF200-08 filter, GAR200-08 regulator, GAL200-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure cylinders handling delicate electronics where a 5 um element protects tiny precision valves from grit.
Conditions air for benchtop analytical instruments requiring stable 0.4 MPa supply and automatic condensate removal.
Regulates sensitive air bearings on yarn guides, using the nylon bowl to avoid shatter hazards near moving threads.
Choose this assembly for single actuators or small jigs requiring precise low-pressure control and fine 5 um filtration. The 5 um element traps far finer particles than the standard 40 um grade, ideal for sensitive instrument air, though it requires more frequent element service. Because the lubricator adds oil mist downstream, select a separate filter-regulator if your line must remain strictly oil-free. Should a component fail, order the GAF200-08 filter, GAR200-08 regulator and GAL200-08 lubricator individually instead of replacing the whole bracket. Stepping up to the GAC300 body increases the plotted flow envelope from 1750 L/min to 3000 L/min at 0.7 MPa inlet, a 1.7x jump in capacity. Finally, note that the 0.4 MPa upper limit is 44% of the Standard type's 0.9 MPa ceiling, so verify your machine will never need more pressure.
AirtacDistr lists every GAC200-08 order code with its price on one page at https://airtacdistr.com/products/airtac-gac200-08-three-unit-frl
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit operates at 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It has a 1/4in port, a 5 um element, a 25 cc drain bowl and a 36 cc oil bowl. The temperature range is -5 to 70 C, the recommended lubricant is ISO VG 32, and it weighs 750 g.
The automatic drain clears accumulated water from the 25 cc bowl on its own, which is decisive for unattended or wet lines. The lower-pressure type caps the regulating range at 0.4 MPa; if your machine might ever require more, this is the wrong part, as the L type cannot reach the 0.9 MPa standard ceiling.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.