The AirTAC Airtac GAC F.R.L. Unit GAC200N08SWK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, pressure-set and oil-misted air for downstream pneumatics, the AirTAC GAC200N08SWK integrates a filter, regulator and lubricator on a single L-shape bracket. This assembly uses a 1/4in port and a 5 um element to trap fine particles, while the standard type regulates pressure from 0.15-0.9 MPa (20-130 psi). Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling of the internal valving.
Weighing 750 g, this compact unit carries a 25 cc condensate bowl and a 36 cc oil reservoir, making it suitable for single actuators or small jigs. The nylon bowl and PT thread are fitted with a circular gauge reading MPa/psi, and a reverse-flow (reflux) valve is included as a distinct pneumatic symbol. The 5 um filtration grade demands more frequent element service than the 40 um default, trading maintenance time for stricter air purity.
| Model | Airtac GAC F.R.L. Unit GAC200N08SWK |
|---|---|
| Series | GAC200 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 750 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF200-08 filter, GAR200-08 regulator, GAL200-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAC300 (curve to 3000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds single small-bore cylinders in assembly jigs where a 5 um element protects precision sliding parts from grit.
Conditions air for benchtop test rigs, using the 1/4in port and nylon bowl to keep instrumentation supplied with stable pressure.
Supplies individual pneumatic screwdrivers or small grinders, adding the necessary oil mist downstream of the regulator.
Choose this 1/4in port model for light-duty tasks, stepping up to the GAC300 if your line needs the 3000 L/min plotted flow envelope rather than the 1750 L/min curve provided here at 0.7 MPa inlet. The nylon bowl keeps the mass at 750 g, while the semi-auto and manual drain pairing gives dual condensate management options. If the downstream line must remain oil-free, omit the lubricator and select a filter-regulator instead. The fitted gauge reads in MPa/psi for the default PT thread, and replacement spares follow the GAF200-08, GAR200-08 and GAL200-08 codes. With a 1.0 MPa maximum supply and a 0.9 MPa standard ceiling, there is only about 0.1 MPa of regulation headroom, so plan an inlet pressure near the maximum if you truly need the highest outlet setting.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This model operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, the drain bowl holds 25 cc, the oil bowl holds 36 cc, the unit weighs 750 g, and the recommended lubricant is ISO VG 32.
The W indicates a 5 um filtering element, which catches finer particles than the standard 40 um grade but requires more frequent element changes. The K signifies that a reverse-flow (reflux) valve is fitted, shown as a separate pneumatic symbol in the catalogue.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.