The AirTAC GAC F.R.L. Unit GAC300C08ALN is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this GAC300C08ALN assembly integrates a filter, regulator and lubricator on a single L-shape bracket. It features a 1/4in port, a 40 um element and a metal bowl. Because the type code is L, the pressure range is 0.15-0.4 MPa (20-58 psi). The automatic drain clears condensate without an operator, which is decisive for unattended or wet lines.
Air passes through the filter, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the oil never fouls the regulator seat. The N in the option string means no gauge is supplied; the gauge connection is 1/8in if one is added later. The unit weighs 1300 g and carries a 60 cc drain bowl alongside a 98 cc oil bowl. Spares follow the same body-port suffix: GAF300-08, GAR300-08 and GAL300-08.
| Model | Airtac GAC F.R.L. Unit GAC300C08ALN |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-08 filter, GAR300-08 regulator, GAL300-08 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 1/4" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds small clamping cylinders on assembly jigs where delicate part holding requires a regulated pressure capped at 0.4 MPa.
Conditions air for sensitive test fixtures, using the 40 um element to protect precision valves from particulate ingress.
Supplies oil mist to low-pressure sealing or folding mechanisms, with the automatic drain handling condensate in wet plant air.
Choose this lower-pressure type for machines operating within 0.15-0.4 MPa (20-58 psi); if the equipment may ever need more, the L type is the wrong part. The metal bowl suits harsher environments, while the 40 um element balances standard filtration with longer service intervals. Since no gauge is supplied, the set pressure cannot be read without adding one to the 1/8in connection. If the downstream line must stay oil-free, the lubricator must be omitted and a filter-regulator chosen instead. Stepping up to the GAC400 roughly doubles the plotted flow envelope to 6000 L/min at 0.7 MPa inlet compared to this body's 3000 L/min. Choosing the L type means the 0.4 MPa ceiling is 44% of the Standard type's 0.9 MPa maximum.
AirtacDistr lists every GAC300-08 order code with its price on one page at https://airtacdistr.com/products/airtac-gac300-08-three-unit-frl
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi). It has a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The operating temperature is -5 to 70 C. It features a 60 cc drain bowl, a 98 cc oil bowl, and weighs 1300 g. The recommended lubricant is ISO VG 32.
The N after the port in the model code indicates no gauge is supplied. To read the set pressure, an operator must add a separate gauge to the 1/8in connection on the regulator body. The default PT thread sets the gauge scale to MPa/psi if one is installed.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.